MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s13052-025-02143-z

Медицинская библиотека · Italian journal of pediatrics · 2025

Flow-synchronized nasal intermittent positive pressure ventilation for prevention of extubation failure in neonates: a review of literature and a case series of neonates with congenital diaphragmatic hernia successfully managed with this strategy.

Ronci Sara, Caoci Stefano, Gizzi Camilla, Calzolari Flaminia, Capolupo Irma, De Rose Domenico Umberto, Maddaloni Chiara, Martini Ludovica, Savignoni Ferdinando, Moretti Corrado, Dotta Andrea

СтатьяОбзорКлинический случайПеревод в очереди

Аннотация

BACKGROUND

Advances in neonatal medicine have improved survival rates in neonatal intensive care units, especially for high-complexity cases like congenital diaphragmatic hernia (CDH). Despite these advances, managing respiratory failure in CDH infants remains challenging due to lung hypoplasia, respiratory insufficiency, and pulmonary hypertension. Lung-protective ventilation strategies are crucial to minimize ventilator-induced lung injury, but weaning them from invasive mechanical ventilation remains complex, and extubation failure rates are high.

CASE PRESENTATION: This retrospective case series describes the use of Flow-Synchronized Nasal Intermittent Positive Pressure Ventilation (sNIPPV) in four neonates with surgically corrected left CDH admitted to the "Bambino Gesù" Children's Hospital in Rome (Italy) from 2022 onwards. Flow-sNIPPV was administered using the Giulia® ventilator, which features a flow sensor for synchronization. We observed improved outcomes in terms of extubation success, in comparison to non-synchronized Nasal Intermittent Positive Pressure Ventilation (NIPPV). Synchronization reduced work of breathing (WOB), improved lung ventilation, and enhanced gas exchange without increasing ventilation-related complications. Additionally, this study reviews the current literature on the use of sNIPPV in neonates, highlighting the need for more research on its role in weaning post-extubation in CDH infants.

CONCLUSIONS

Flow-sNIPPV shows promise in preventing extubation failure in neonates with CDH by improving ventilation and reducing WOB. Synchronization enhances lung ventilation, stabilizes the chest wall, and may reduce thoraco-abdominal asynchrony in CDH infants. While the findings are promising, larger multicenter studies are required to confirm the efficacy and safety of sNIPPV as a routine weaning strategy in CDH neonates after repair surgery.

Для цитирования: Ronci Sara, Caoci Stefano, Gizzi Camilla, Calzolari Flaminia, Capolupo Irma, De Rose Domenico Umberto, Maddaloni Chiara, Martini Ludovica, Savignoni Ferdinando, Moretti Corrado, Dotta Andrea. Flow-synchronized nasal intermittent positive pressure ventilation for prevention of extubation failure in neonates: a review of literature and a case series of neonates with congenital diaphragmatic hernia successfully managed with this strategy.. Italian journal of pediatrics. 2025. DOI: 10.1186/s13052-025-02143-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.