MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jelectrocard.2026.154272

Медицинская библиотека · Journal of electrocardiology · 2026

Evaluation of new vectorcardiography algorithms for identifying left ventricular hypertrophy and impaired systolic function.

Salatzki Janek, Schwarz Arne Kristian, Wolfsteller Sarah, Hein Nicolas, Medina Erika Poyo, Frey Norbert, Steen Henning, André Florian, Passow Alexander

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Timely diagnosis of impaired systolic function and left ventricular hypertrophy (LVH) remains a clinical challenge. Routine electrocardiography provides limited diagnostic accuracy for detecting early or subtle structural abnormalities. Vectorcardiography (VCG), which captures the spatial and temporal characteristics of cardiac electrical activation and repolarization, may offer a rapid, scalable, and cost-effective alternative for screening structural heart disease.

OBJECTIVE

To evaluate the diagnostic performance of VCG for identifying impaired systolic function and left ventricular hypertrophy compared with cardiac magnetic resonance imaging.

METHODS

This prospective case-control study included 245 participants undergoing both CMR and VCG. Among 245 participants, 40 had reduced LVEF (<40%) and 208 met CMR criteria for LVH; 34 patients had both conditions. Patients were classified as having impaired systolic function (left ventricular ejection fraction [LVEF] <40%), LVH (indexed left ventricular mass ≥ 55 g/m2), or controls with structurally normal hearts. VCG was obtained using a five‑lead system (cardisiography), and signals were processed by an AI algorithm extracting 583 parameters. Diagnostic performance was evaluated using CMR as reference.

RESULTS

The repolarization time-difference ratio (Rpeak-Tonset / QRSend-Tpeak) showed the best diagnostic performance for impaired systolic function, with an area under the curve (AUC) of 0.843, sensitivity of 80.0%, and specificity of 83.9%. In LVH patients, three parameters-T-wave azimuth, T-wave magnitude, and azimuth variability-showed AUCs ranging from 0.739 to 0.791. Overall diagnostic accuracy was 81.7% for impaired systolic function and 78.2% for LVH, and 83.1% for the combined phenotype of reduced LVEF and LVH.

CONCLUSION

VCG reliably detects left ventricular systolic dysfunction and hypertrophy. This approach offers a scalable and interpretable screening tool, especially valuable in settings with limited access to advanced cardiac imaging. Future multicenter studies are needed to validate these findings and support clinical implementation.

Для цитирования: Salatzki Janek, Schwarz Arne Kristian, Wolfsteller Sarah, Hein Nicolas, Medina Erika Poyo, Frey Norbert, Steen Henning, André Florian, Passow Alexander. Evaluation of new vectorcardiography algorithms for identifying left ventricular hypertrophy and impaired systolic function.. Journal of electrocardiology. 2026. DOI: 10.1016/j.jelectrocard.2026.154272.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.