DOI 10.1371/journal.pone.0352430
Comparison of two algorithms of APTT-based lupus anticoagulant assay, two Dilute Russell viper venom time reagents, and silica clotting time.
Аннотация
Lupus anticoagulants (LA) are heterogeneous antiphospholipid antibodies that interfere with phospholipid-dependent coagulation assays, resulting in considerable variability among detection methods. Although international guidelines recommend a stepwise approach incorporating screening, mixing, and confirmatory testing, integrated strategies omitting routine mixing studies are widely used. Different percentile-based cutoffs have been proposed for defining LA positivity.We retrospectively analyzed 135 citrated plasma samples requested for LA testing. Five LA detection approaches were evaluated: 4 integrated assays and 1 activated partial thromboplastin time (APTT)-based approach following the ISTH-recommended stepwise algorithm with a mixing study. The integrated assays comprised silica clotting time, dilute Russell viper venom time (dRVVT) using 2 different reagent systems, and an APTT-based assay. Precision studies and reference intervals were established, and LA positivity rates were compared using 97.5th and 99th percentile cutoffs. Inter-assay agreement and associations with anticardiolipin (aCL) and anti-β2-glycoprotein I (aβ2GPI) antiphospholipid antibodies were assessed. LA positivity rates varied across procedures (19.3%-35.6%) at the 97.5th percentile. Application of the 99th percentile decreased positivity for dRVVT-HemosIL and APTT-based assays. Positivity increased at the 97.5th percentile in patients tested according to ISTH indications, with minimal impact in noncompliant cases. Inter-assay agreement ranged from fair to substantial and was influenced by assay type and cutoff definition. APTT-based assays showed the strongest associations with aCL and aβ2GPI antibodies. LA detection is strongly influenced by assay selection and cutoff strategy. Positivity rate-based evaluation provides a practical framework for comparing LA assays in laboratory practice, particularly in the absence of a reference standard.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.