Improved Extraction Repeatability and Spectral Reproducibility for Liquid Extraction Surface Analysis-Mass Spectrometry Using Superhydrophobic-Superhydrophilic Patterning.

Meurs Joris, Alexander Morgan R, Levkin Pavel A, Widmaier Simon, Bunch Josephine, Barrett David A, Kim Dong-Hyun

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

A major problem limiting reproducible use of liquid extraction surface analysis (LESA) array sampling of dried surface-deposited liquid samples is the unwanted spread of extraction solvent beyond the dried sample limits, resulting in unreliable data. Here, we explore the use of the Droplet Microarray (DMA), which consists of an array of superhydrophilic spots bordered by a superhydrophobic material giving the potential to confine both the sample spot and the LESA extraction solvent in a defined area. We investigated the DMA method in comparison with a standard glass substrate using LESA analysis of a mixture of biologically relevant compounds with a wide mass range and different physicochemical properties. The optimized DMA method was subsequently applied to urine samples from a human intervention study. Relative standard deviations for the signal intensities were all reduced at least 3-fold when performing LESA-MS on the DMA surface compared with a standard glass surface. Principal component analysis revealed more tight clusters indicating improved spectral reproducibility for a human urine sample extracted from the DMA compared to glass. Lastly, in urine samples from an intervention study, more significant ions (145) were identified when using LESA-MS spectra of control and test urine extracted from the DMA. We demonstrate that DMA provides a surface-assisted LESA-MS method delivering significant improvement of the surface extraction repeatability leading to the acquisition of more robust and higher quality data. The DMA shows potential to be used for LESA-MS for controlled and reproducible surface extraction and for acquisition of high quality, qualitative data in a high-throughput manner.

Для цитирования: Meurs Joris, Alexander Morgan R, Levkin Pavel A, Widmaier Simon, Bunch Josephine, Barrett David A, Kim Dong-Hyun. Improved Extraction Repeatability and Spectral Reproducibility for Liquid Extraction Surface Analysis-Mass Spectrometry Using Superhydrophobic-Superhydrophilic Patterning.. Analytical chemistry. 2018. DOI: 10.1021/acs.analchem.8b00973.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.