MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2169/internalmedicine.0507-22

Медицинская библиотека · Internal medicine (Tokyo, Japan) · 2023

Evaluating Risk Factors for Developing Allergic Reactions during Plasma Exchange Using Fresh-frozen Plasma: A Single-center Retrospective Study.

Abe Tetsuya, Aoyama Togo, Takeuchi Yasuo

СтатьяПеревод в очереди

Аннотация

Objective Allergic reactions are a severe complication of plasma exchange (PEx). Few reports have analyzed allergic reactions during PEx using fresh-frozen plasma (FFP) as a replacement solution. We therefore clarified the relationship between risk and exacerbation factors that lead to the onset of PEx-related allergic reactions, particularly PEx, using FFP, and examined whether or not allergic reactions were predictable. Methods This retrospective study included 88 consecutive patients who underwent PEx with FFP as a replacement solution at Kitasato University Hospital. The patients were grouped according to the presence of allergic reactions and compared. Data were analyzed using the χ2 test, Mann-Whitney U test, and a binomial logistic analysis. Statistical analyses were performed using EZR software program, version 1.54, with p<0.05 considered statistically significant. Results There were 44 allergic reaction cases. The average time to the onset of an allergic reactions was 63.5 (45-93) minutes. The allergic reaction-onset group had significantly higher average albumin (Alb) levels than did the non-allergic reaction-onset group. The binomial logistic analysis identified Alb levels as independent risk factors for allergic reactions. The receiver operating characteristic analysis identified an Alb level ≥3.4 g/dL as a risk factor for allergic reactions (area under the curve: 0.731; 95% confidence interval: 0.622-0.84). Conclusion Allergic reaction onset occurred approximately one hour after PEx initiation in the critical period. A serum Alb level ≥3.4 g/dL was identified as a risk factor for predicting allergic reactions. Patients with Alb levels ≥3.4 g/dL at the first PEx should be monitored for allergic reaction symptoms.

Для цитирования: Abe Tetsuya, Aoyama Togo, Takeuchi Yasuo. Evaluating Risk Factors for Developing Allergic Reactions during Plasma Exchange Using Fresh-frozen Plasma: A Single-center Retrospective Study.. Internal medicine (Tokyo, Japan). 2023. DOI: 10.2169/internalmedicine.0507-22.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.