MedElevator Войти в исследования
← Поиск публикаций

DOI 10.7759/cureus.96591

Медицинская библиотека · Cureus · 2025

Efficacy of Standard Biophysical Tests in Assessing Fetal Oxygenation Status.

Cancarevic Djajic Branka, Draganovic Dragica, Milic-Radic Tanja, Sobot Suzana, Popovic Bojana, Milidragovic Jelena, Vjestica Milan, Bozic Stefan, Preradovic Ljubisa

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Timely recognition of fetal oxygenation disorders is essential to prevent irreversible injury. Cardiotocography (CTG) and biophysical profile (BPP) are widely used for fetal surveillance, yet their diagnostic and predictive performance relative to umbilical artery (UA) pH and neonatal outcomes warrants further evaluation. This study assessed the efficacy of CTG and BPP in predicting fetal acidosis and a low one-minute Apgar score (AS) and examined their value for identifying fetal hypoxia and asphyxia.

MATERIAL AND

METHODS

We conducted a retrospective study of 119 hospitalized pregnant women at the Department of Perinatology, University Clinical Center of the Republic of Srpska in Banja Luka, with gestational age ≥ 27 weeks, singleton pregnancies, and no fetal malformations. CTG tracings were classified as normal, equivocal, or pathological. The BPP was scored (0-10) and categorized as normal, equivocal, or pathological. We correlated test results with UA pH (acidosis < 7.20; pre-acidosis 7.20-7.24; normal ≥ 7.25) and the one-minute AS. We calculated sensitivity, specificity, positive predictive value, negative predictive value, and accuracy, and used appropriate significance tests.

RESULTS

CTG and BPP showed similar predictive performance for detecting acidosis and a low one-minute AS. Both methods demonstrated statistically significant associations with UA pH and AS (p < 0.001). Perinatal mortality was 1.68% and morbidity was 24.37%; fatal outcomes were associated with pathological findings on both tests, acidosis, and a low AS.

CONCLUSION

CTG and BPP are useful predictors of fetal hypoxia and asphyxia. Integrated use and careful interpretation of both tests can aid in identifying compromised fetuses and guiding timely decisions about the mode and timing of delivery, with the potential to reduce adverse perinatal outcomes.

Для цитирования: Cancarevic Djajic Branka, Draganovic Dragica, Milic-Radic Tanja, Sobot Suzana, Popovic Bojana, Milidragovic Jelena, Vjestica Milan, Bozic Stefan, Preradovic Ljubisa. Efficacy of Standard Biophysical Tests in Assessing Fetal Oxygenation Status.. Cureus. 2025. DOI: 10.7759/cureus.96591.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.