Successful Treatment of Extracorporeal Membrane Oxygenation Induced Digital Ischemia in Infants Using Botulinum Toxin Type A.

Huang Samantha, Byrd Dominick, Laarakker Avra, Shahriari Shawhin, Borah Gregory

СтатьяКлинический случайПеревод в очереди

Аннотация

Digital ischemia following extracorporeal membrane oxygenation (ECMO) therapy is a known complication with potential devastating long-term sequela. Onabotulinum toxin type A (BTX-A) has been demonstrated to be effective for digital ischemia in adults with Raynaud's phenomenon. The objective of this study is to describe the use of BTX-A in pediatric and neonatal patients with digital ischemia following ECMO therapy. Three consecutive patients with digital ischemia after ECMO therapy were included. Patient ages ranged from 3 days to 13 months. Twenty-five to 50 units of BTX-A were injected to each affected extremity targeting the areas around the known arterial anatomy of the hands and feet. On post-injection day one, all patients demonstrated improvement in ischemic discoloration. Complete resolution was noted by treatment day 3 in one case and near complete resolution by day 16 in the second. Case 3 expired on hospital day four from an unrelated intracranial hemorrhage. No complications or digital loss were observed. Onabotulinum toxin type A as an off-label treatment for digital ischemia was demonstrated to be safe and effective in pediatric and neonatal patients. Clinical improvement was noted in all patients by post-procedure day one, with two patients demonstrating near to complete resolution within 3 weeks.

Для цитирования: Huang Samantha, Byrd Dominick, Laarakker Avra, Shahriari Shawhin, Borah Gregory. Successful Treatment of Extracorporeal Membrane Oxygenation Induced Digital Ischemia in Infants Using Botulinum Toxin Type A.. ASAIO journal (American Society for Artificial Internal Organs : 1992). 2025. DOI: 10.1097/mat.0000000000002510.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.