BACKGROUND

Patent foramen ovale (PFO) affects 20%-34% of adults and is associated with strokes and other disorders. The conventional treatment of PFO-related strokes is a closure procedure. The metal device is associated with some adverse events.

OBJECTIVE

Our aim was to investigate the efficacy and safety of PFO closure using cryoablation without implantation in patients with atrial fibrillation (AF) who underwent pulmonary vein isolation (PVI).

METHODS

We divided the 22 patients with both PFO and AF who underwent PVI via cryoablation into 2 groups: standard PVI + atrial septal (AS) cryoablation group (group 1, n = 11) and standard PVI group (group 2, n = 11). The guidewire accesses the left atrium through the PFO without AS puncture during the procedure. Standard PVI via cryoablation was performed. The cryoballoon was retracted to the right atrium and inflated against the AS post-PVI. Patients in group 1 had cryoablation for 120-150 seconds, whereas patients in group 2 received sham ablation. The co-primary end points were the PFO closure rate and a composite of AF recurrence and stroke/transient ischemic attack (TIA) events.

RESULTS

There were no differences in procedure-related adverse events between the 2 groups. Neither group had an ischemic stroke report at 1-year follow-up. The PFO closure rate at 6 months in group 1 was significantly higher than that in group 2 (7 [63.6%] vs 1 [9.1%]; P = .002). AF recurrence post ablation was comparable in both groups at 3 months (3 [27.3%] vs 1 [9.1%]; P = .269), 6 months (0 vs 0), and 12 months (2 [18.2%%] vs 1 [9.1%]; P = .534) of follow-up.

CONCLUSION

Cryoablation is a safe and effective approach to close PFO in patients with AF undergoing PVI in a single procedure.

Для цитирования: Deng Jiang, Wang EnRun, Liu Gang, Qin ChunChang, Dong Qian, Yang Wei, Wang YanFei, Abdul Qadir Rana, Jia Fengpeng. Feasibility and safety of cryoballoon ablation for atrial fibrillation and closing patent foramen ovale without implantation: A pilot study.. Heart rhythm. 2024. DOI: 10.1016/j.hrthm.2024.06.006.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.