Relationship between chest port catheter tip position and port malfunction after interventional radiologic placement.

Schutz Jakob C L, Patel Aalpen A, Clark Timothy W I, Solomon Jeffrey A, Freiman David B, Tuite Catherine M, Mondschein Jeffrey I, Soulen Michael C, Shlansky-Goldberg Richard D, Stavropoulos S William, Kwak Andrew, Chittams Jesse L, Trerotola Scott O

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: The relationship between catheter tip position of implanted subcutaneous chest ports and subsequent port malfunction was investigated. Tip movement from initial supine position to subsequent erect position was also evaluated.

MATERIALS AND

METHODS

Patients who underwent imaging-guided internal jugular chest port placement between July 2001 and May 2003 were identified with use of a quality-assurance database. Sixty-two patients were included in the study (22 men and 40 women), with a mean age of 58 years (range, 27-81 years). Catheter tip location on the intraprocedural chest radiograph was determined with use of two methods. First, the distance from the right tracheobronchial angle (TBA) was recorded (TBA distance). Second, tip location was classified into six anatomic regions: 1, internal jugular veins; 2, brachiocephalic veins; 3, superior vena cava (SVC; n = 11); 4, SVC/right atrial junction (n = 22); 5, upper half of right atrium (n = 25); and 6, lower half of right atrium (n = 4). For the duration of follow-up, catheter tip location was documented, as were all episodes of catheter malfunction.

RESULTS

Patients with catheter tips initially placed in position 3 had a higher risk of port malfunction (four of 11; 36%) than patients with catheter tips located in position 5 (two of 25; 8%). This difference narrowly fell short of statistical significance (P =.057). When comparing intraprocedural chest radiographs to the first erect chest radiographs, significant upward tip movement was noted. The tips migrated cephalad an average of 20 mm (P =.003) and 1.0 position units (P =.001).

DISCUSSION: Catheter tips placed in the SVC tended to have a greater risk of port malfunction compared with those positioned in the right atrium. Chest ports migrated cephalad between the supine and erect positions.

Для цитирования: Schutz Jakob C L, Patel Aalpen A, Clark Timothy W I, Solomon Jeffrey A, Freiman David B, Tuite Catherine M, Mondschein Jeffrey I, Soulen Michael C, Shlansky-Goldberg Richard D, Stavropoulos S William, Kwak Andrew, Chittams Jesse L, Trerotola Scott O. Relationship between chest port catheter tip position and port malfunction after interventional radiologic placement.. Journal of vascular and interventional radiology : JVIR. 2004. DOI: 10.1097/01.rvi.0000127890.47187.91.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.