MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcct.2022.05.003

Медицинская библиотека · Journal of cardiovascular computed tomography · 2022

Systolic or diastolic CT image acquisition for transcatheter aortic valve replacement - An outcome analysis.

Steffen Julius, Beckmann Markus, Haum Magda, Fischer Julius, Andreae David, Orban Mathias, Rizas Konstatinos, Braun Daniel, Orban Martin, Curta Adrian, Hagl Christian, Theiss Hans D, Mehilli Julinda, Massberg Steffen, Deseive Simon, Hausleiter Jörg

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Computed tomography (CT) imaging is the standard of care before transcatheter aortic valve replacement (TAVR). The aortic annulus undergoes conformational changes during the heart cycle. Therefore, the image acquisition time point can impact prosthesis sizing and fit. Clinical outcome data are lacking. The aim of this study was to compare systolic and diastolic cardiac CT data acquisition with regard to procedural and clinical outcomes in patients undergoing TAVR for severe aortic stenosis (AS).

METHODS

Preprocedural high-pitch helical CT datasets were analyzed in 1954 patients undergoing TAVR between 2013 and 2018 ​at our center. Patients were stratified into two groups according to the acquisition heart phase (979 systolic and 975 diastolic). The study was approved by the local ethics committee.

RESULTS

Median age was 81.6 [interquartile range 77.5-85.8] years and 964 (49.3%) patients were male. No significant difference was found for the Valve Academic Research Consortium-3 (VARC-3) endpoints of technical failure (systolic, 5.1% vs. diastolic, 5.2%, p ​= ​0.94) or device failure (systolic, 13.7% vs. diastolic, 13.5%, p ​= ​0.92). There was no difference in paravalvular regurgitation. All-cause 30-day mortality was comparable (systolic, 3.6% [95% confidence interval, 2.4-4.7%] vs. diastolic, 3.6% [2.4-4.8%], p ​= ​1.00), while 3-year mortality rates were higher in the diastolic group (Society of Thoracic Surgeons score adjusted hazard ratio, 1.25 [1.07-1.46], p ​< ​0.01).

CONCLUSIONS

While the 30-day technical and clinical outcomes after TAVR are comparable between systolic and diastolic CT imaging, diastolic imaging was associated with higher long-term mortality. Therefore, the data support the guideline recommendation of systolic imaging.

Для цитирования: Steffen Julius, Beckmann Markus, Haum Magda, Fischer Julius, Andreae David, Orban Mathias, Rizas Konstatinos, Braun Daniel, Orban Martin, Curta Adrian, Hagl Christian, Theiss Hans D, Mehilli Julinda, Massberg Steffen, Deseive Simon, Hausleiter Jörg. Systolic or diastolic CT image acquisition for transcatheter aortic valve replacement - An outcome analysis.. Journal of cardiovascular computed tomography. 2022. DOI: 10.1016/j.jcct.2022.05.003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.