MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/0363546520919120

Медицинская библиотека · The American journal of sports medicine · 2020

Long-term Results of Arthroscopic Rotator Cuff Repair: A Follow-up Study Comparing Single-Row Versus Double-Row Fixation Techniques.

Plachel Fabian, Siegert Paul, Rüttershoff Katja, Thiele Kathi, Akgün Doruk, Moroder Philipp, Scheibel Markus, Gerhardt Christian

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

Arthroscopic rotator cuff repair (RCR) with suture anchor-based fixation techniques has replaced former open and mini-open approaches. Nevertheless, long-term studies are scarce, and lack of knowledge exists about whether single-row (SR) or double-row (DR) methods are superior in clinical and anatomic results.

PURPOSE: To analyze long-term results after arthroscopic RCR in patients with symptomatic rotator cuff tears and to compare functional and radiographic outcomes between SR and DR repair techniques at least 10 years after surgery.

STUDY

DESIGN

Cohort study; Level of evidence, 3.

METHODS

Between 2005 and 2006, 40 patients with a symptomatic full-thickness rotator cuff tear (supraspinatus tendon tear with or without a tear of the infraspinatus tendon) underwent arthroscopic RCR with either an SR repair with a modified Mason-Allen suture-grasping technique (n = 20) or a DR repair with a suture bridge fixation technique (n = 20). All patients were enrolled in a long-term clinical evaluation, with the Constant score (CS) as the primary outcome measure. Furthermore, an ultrasound examination was performed to assess tendon integrity and conventional radiographs to evaluate secondary glenohumeral osteoarthritis.

RESULTS

A total of 27 patients, of whom 16 were treated with an SR repair and 11 with a DR repair, were followed up after a mean ± SD period of 12 ± 1 years (range, 11-14 years). Five patients underwent revision surgery on the affected shoulder during follow-up period, which led to 22 patients being included. The overall CS remained stable at final follow-up when compared with short-term follow-up (81 ± 8 vs 83 ± 19 points; P = .600). An increasing number of full-thickness retears were found: 6 of 22 (27%) at 2 years and 9 of 20 (45%) at 12 years after surgery. While repair failure negatively affected clinical results as shown by the CS (P < .05), no significant difference was found between the fixation techniques (P = .456). In general, progressive osteoarthritic changes were observed, with tendon integrity as a key determinant.

CONCLUSION

Arthroscopic RCR with either an SR or a DR fixation technique provided good clinical long-term results. Repair failure was high, with negative effects on clinical results and the progression of secondary glenohumeral osteoarthritis. While DR repair slightly enhanced tendon integrity at long-term follow-up, no clinical superiority to SR repair was found.

Для цитирования: Plachel Fabian, Siegert Paul, Rüttershoff Katja, Thiele Kathi, Akgün Doruk, Moroder Philipp, Scheibel Markus, Gerhardt Christian. Long-term Results of Arthroscopic Rotator Cuff Repair: A Follow-up Study Comparing Single-Row Versus Double-Row Fixation Techniques.. The American journal of sports medicine. 2020. DOI: 10.1177/0363546520919120.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.