MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2106/jbjs.cc.20.00082

Медицинская библиотека · JBJS case connector · 2020

Arthroscopic Repair of a Displaced Tuberosity Fragment After Proximal Humerus Locking Plate Fixation: A Case Report.

Dillon Mark T, Madden Ross P

Клинический случайСтатьяПеревод в очереди

Аннотация

CASE: Locking plate fixation of proximal humerus fractures is known to have high complication rates. Even a technically well-performed surgery can be subject to loss of reduction, which can lead to an adverse functional outcome for the patient. In this case report, we describe a patient who underwent open reduction and internal fixation of a proximal humerus fracture complicated by delayed loss of reduction of a greater tuberosity fragment that was revised using arthroscopic techniques.

CONCLUSION

Arthroscopic repair of displaced greater tuberosity fragments after failed locking plate fixation of proximal humerus fractures can lead to good functional outcomes at 1-year follow-up.

Для цитирования: Dillon Mark T, Madden Ross P. Arthroscopic Repair of a Displaced Tuberosity Fragment After Proximal Humerus Locking Plate Fixation: A Case Report.. JBJS case connector. 2020. DOI: 10.2106/jbjs.cc.20.00082.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.