Video head impulse and suppression head impulse test in vestibular migraine.

Özçelik Pınar, Koçoğlu Koray, Halmágyi Gábor M, Akdal Gülden

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Vestibular Migraine (VM) is a frequent cause of recurrent spontaneous vertigo. While some report a normal Video Head Impulse Test (vHIT) in VM, others observed abnormal results on this test. Whether or not methodological discrepancies could be the cause of these differences is not known. There are 2 vHIT methods: subjects fixating an earth-fixed target (HIMP paradigm) or a head-fixed target, the suppression head impulse test (SHIMP paradigm).

OBJECTIVES

The present study aimed to compare VM patients against healthy controls on both HIMP and SHIMP in order to unravel any differences between them.

METHODS

Forty-eight VM patients and 27 healthy controls tested with both the HIMP and SHIMP paradigm.

Results

Our 48 VM patients showed mean VOR normal range gains in both the HIMP and SHIMP paradigms, although there were some VOR impairments in individual semicircular SCCs. VM patients with motion sickness had lower horizontal VOR gain than those without motion sickness, with the HIMP, but not the SHIMP paradigm.

CONCLUSION

VM patients have normal VOR gain with either vHIT paradigm.

SIGNIFICANCE: The clinical significance of this observation is that a definitely abnormal vHIT with either method is unlikely to be due to vestibular migraine and an alternative diagnosis should be sought.

Для цитирования: Özçelik Pınar, Koçoğlu Koray, Halmágyi Gábor M, Akdal Gülden. Video head impulse and suppression head impulse test in vestibular migraine.. Acta oto-laryngologica. 2024. DOI: 10.1080/00016489.2023.2284877.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.