INTRODUCTION

This study aimed to characterize the use of temporary mechanical circulatory support (tMCS) among patients undergoing transcatheter aortic valve replacement (TAVR) using a nationally representative database.

MATERIALS AND

METHODS

The 2012-2018 National Inpatient Sample was queried for adult patients who underwent isolated TAVR. The tMCS group was comprised of those who required extracorporeal membrane oxygenation, percutaneous ventricular assist device, or intra-aortic balloon pump during index hospitalization. We evaluated temporal trends in the utilization of tMCS using Cuzick's test. Furthermore, a multivariable logistic regression was used to identify factors associated with tMCS use and its impact on in-hospital mortality, selected complications, and nonhome discharge.

RESULTS

Of an estimated 215,925 patients who underwent TAVR, 3085 (1.4%) required tMCS during their hospital course. The most common modality of tMCS was intra-aortic balloon pump (49%), followed by extracorporeal membrane oxygenation (27%) then percutaneous ventricular assist device (18%). Seven percent of tMCS patients were supported by > 1 device. The annual incidence of tMCS usage decreased over the study period, from 3% in 2012 to 1% in 2018 (P-trend < 0.01). Nonelective admission, congestive heart failure, coagulopathy, and liver disease were strong independent predictors of requiring tMCS. Patients requiring tMCS had a 31.8% in-hospital mortality rate (adjusted odds ratio = 23, 95% confidence interval 18.5-28.5), longer length of stay (9 d versus 3, P < 0.001), and higher costs ($84,600 versus $48,100, P < 0.001) than those who did not.

CONCLUSIONS

The use of tMCS during TAVR has decreased over time but remains associated with a 23-fold increased mortality rate and significant clinical and resource utilization burden.

Для цитирования: Shou Benjamin L, Verma Arjun, Florissi Isabella S, Schena Stefano, Benharash Peyman, Choi Chun Woo. Temporary Mechanical Circulatory Support for Transcatheter Aortic Valve Replacement.. The Journal of surgical research. 2022. DOI: 10.1016/j.jss.2022.07.034.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.