MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1046/j.1469-0705.1997.10040269.x

Медицинская библиотека · Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology · 1997

Sonographic measurement of the fetal rib cage perimeter to thoracic circumference ratio: application to prenatal diagnosis of skeletal dysplasias.

Dugoff L, Coffin C T, Hobbins J C

СтатьяПеревод в очереди

Аннотация

The object of this study was to establish new normative data for the fetal rib cage perimeter to thoracic circumference ratio, and to evaluate the potential application of this measurement in the diagnosis of short rib and other skeletal dysplasias. Rib cage perimeter (RCP) and thoracic circumference (TC) were measured in a prospective, cross-sectional sample of 88 patients with normal pregnancies between 14 and 39 weeks of gestation. The RCP and TC were both measured in cross-section, at a level of the four-chamber view of the fetal heart. RCP and TC measurements were also obtained from eight cases known to have skeletal dysplasias. The mean (+/- SE) RCP:TC ratio in normal pregnancies, regardless of gestational age, was 0.670 +/- 0.004. In five of eight cases with skeletal dysplasias the RCP:TC ratio was significantly decreased, and in one case it was increased. The RCP:TC ratio in normal fetuses is independent of gestational age. In this small series the ratio was abnormal in fetuses with certain skeletal dysplasias, and particularly decreased in the fetus with a short rib-polydactyly syndrome. After further evaluation, this technique may prove to be of clinical significance in helping to diagnose skeletal dysplasias, particularly in cases where the gestational age is uncertain.

Для цитирования: Dugoff L, Coffin C T, Hobbins J C. Sonographic measurement of the fetal rib cage perimeter to thoracic circumference ratio: application to prenatal diagnosis of skeletal dysplasias.. Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology. 1997. DOI: 10.1046/j.1469-0705.1997.10040269.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.