Nam Yoojin, An Taein, Il Hwang Sung, Jeon Chawoong, Jeong Ji Won, Jeong Juhyun, Kim Dong Yeong, Kim Pyeong Hwa, Kim So Yeon, Kim Sungkwan, Kim Yangwon, Lee Kwang Hwi, Lee Taehee, Oh Hee Sang, Park Joon Hyung, Shin Seunghyeon, Sim Yongsik, Song Jeong Min, Song Seunghyun, Hong Pa, Kim Namkug

СтатьяПеревод в очереди

Аннотация

Large language models (LLMs) can generate medical educational content at scale, but multi-dimensional human validation of multi-LLM pipelines has not been performed at scale. We evaluated a 7-stage sequential multi-LLM pipeline implemented exclusively with the Gemini family (Gemini 3 Flash and Pro for text; Gemini 3 Pro Image, the Nano Banana Pro preview, for images), producing 6000 flashcards and 833 infographics for radiology board preparation. Nine residents and eleven attending radiologists evaluated 1284 flashcards across 11 subspecialties in a two-phase design around fifth-stage (S5) feedback. Among 1100 evaluations of 980 text-level PASS cards, the evaluation-level false-negative rate (FNR) for blocking errors was 1.00% (95% CI 0.50-1.78%), exceeding the pre-specified 0.3% safety threshold; card-level (1.12%) and majority-vote (0.82%) analyses converged. S5 feedback was associated with increased blocking-error flags (39-54 evaluation-level observations, McNemar p = 0.003) and decreased technical accuracy and educational quality scores (both p < 0.001). In unadjusted analyses, attending radiologists identified more errors than residents (odds ratio 4.52, 95% CI 2.38-8.57), although workload-matched sensitivity analyses attenuated this gap. A preliminary image pilot of 19 items showed critical errors in both tables and infographics, with between-format comparisons underpowered and not significant after Holm correction; this image-related observation should be interpreted as exploratory. The conditional safety estimates, low-reliability reference standard, and rater- and workload-dependent patterns do not support fully automated deployment; automated feedback was associated with sharpened evaluator scrutiny, though the single-arm design cannot isolate useful cueing from anchoring or re-review effects.

Для цитирования: Nam Yoojin, An Taein, Il Hwang Sung, Jeon Chawoong, Jeong Ji Won, Jeong Juhyun, Kim Dong Yeong, Kim Pyeong Hwa, Kim So Yeon, Kim Sungkwan, Kim Yangwon, Lee Kwang Hwi, Lee Taehee, Oh Hee Sang, Park Joon Hyung, Shin Seunghyeon, Sim Yongsik, Song Jeong Min, Song Seunghyun, Hong Pa, Kim Namkug. Human-in-the-loop validation of a sequential multi-LLM medical education pipeline.. NPJ digital medicine. 2026. DOI: 10.1038/s41746-026-02978-8.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.