DOI 10.1016/j.healun.2022.07.006
Left ventricular assist device implantation via lateral thoracotomy: A systematic review and meta-analysis.
Аннотация
BACKGROUND
Left ventricular assist device (LVAD) implantation via lateral thoracotomy can offer similar effectiveness to conventional approaches with less perioperative adverse events. We performed a systematic review and meta-analysis to determine the potential benefits of lateral thoracotomy (LT) for LVAD implantation compared to median sternotomy.
METHODS
We searched MEDLINE and Embase databases for studies comparing continuous-flow LVAD implantation using LT with conventional sternotomy. Main outcomes were perioperative mortality and complications.
RESULTS
Twenty-five observational studies enrolling 3072 patients were included with a median follow-up of 10 months. Perioperative mortality (30 day or in-hospital) was 7% (LT) and 14% (sternotomy); however, mortality differences were no longer statistically significant in matched/adjusted studies (RR:0.86; 95%CI:0.52-1.44; p = 0.58). LT was associated with decreased need for blood product transfusions (mean difference[MD]: -4.7; 95%CI: -7.2 to -2.3 units; p < 0.001), reoperation for bleeding (RR:0.34; 95%CI:0.22-0.54; p < 0.001), postoperative RVAD implantation (RR:0.53; 95%CI:0.36-0.77; p < 0.001), days requiring inotropes (MD: -1.1; 95%CI: -2.1 to -0.03 inotrope days; p = 0.04), ICU (MD: -3.3; 95%CI: -6.0 to -0.7 ICU days; p = 0.01), and hospital length of stay (MD: -5.1; 95%CI: -10.1 to -0.1 hospital days; p = 0.04) in matched/adjusted studies. Overall mortality during follow-up was significantly lower for LT in unmatched/unadjusted studies but not statistically significantly lower in matched/adjusted studies (Hazard Ratio:0.82; 95%CI:0.59-1.14; p = 0.24).
CONCLUSION
LVAD implantation via LT was associated with significantly decreased need for blood products, reoperation for bleeding, and postoperative RVAD implantation. Furthermore, days on inotropic support were also lower, likely contributing to the shorter length of stay. These findings support greater use of a LT approach for carefully selected patients.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.