m+Medelevator.RU
← Поиск публикаций
Cureus · 2025

Results of Lower Limb Bone Lengthening by Using Motorized and Magnet-Driven Intramedullary Nails to Treat Limb Length Discrepancy.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Al-Sayyad Mohammed J, Alshoaibi Fahad A, Alshuaibi Ammar A, Almohammadi Ayman F, Almaghrabi Hatim A, Alsaady Abdullah M, Alsayyad Jalal M

Аннотация

INTRODUCTION: Limb length discrepancies (LLDs) can be treated with limb lengthening using external fixation or intramedullary nails, such as PRECICE or FITBONE. PRECICE is a magnetically driven titanium nail, while FITBONE is a motorized nail; both use an external remote control. This study aimed to determine the complications, compensation of length difference, time needed for compensation, and healing outcome of bone lengthening using motorized or magnet-driven intramedullary nails among non-cosmetic limb lengthening cases.

METHODS: This retrospective study was derived from a single surgeon's practice at a tertiary hospital in Jeddah, Saudi Arabia. Between 2009 and 2020, 15 patients with LLDs, with a mean age of 25.43 years (range 16-35 years), were identified. The study included congenital, post-traumatic, idiopathic, and acquired causes of LLDs. Outcomes were measured using complete lengthening and healing indices, which need the presence of three intact cortices out of four.

RESULTS: All patients achieved correction of their limb length without any device failure or nail breakage. The achieved limb length for all patients averaged 38.4 mm, ranging from 21 to 60 mm. No intraoperative complications were observed. Postoperatively, one patient reported knee stiffness, and another developed deep venous thrombosis. Duration of distraction (average 43.93 days, range 30-66 days) and the mean healing index was 32 days/cm for both the femur and tibia.

CONCLUSION: This study confirms that intramedullary nail PRECICE 2 and FITBONE systems are reliable and effective lengthening devices for treating lower LLDs and deformities. These devices significantly reduce complications and achieve excellent outcomes.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты