MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/pace.70094

Медицинская библиотека · Pacing and clinical electrophysiology : PACE · 2025

Predictors of Atrial High-Rate Episodes and Inappropriate Device Therapy in Implantable Cardioverter Defibrillators.

Huntelaar Marthe J, Hopman Luuk H G A, van der Lingen Anne-Lotte C J, Rijnierse Mischa T, Kemme Michiel J B, Allaart Cornelis P, van Halm Vokko P

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Implantable cardioverter defibrillator (ICD) therapy can prevent sudden cardiac death, but poses a risk of inappropriate device therapy (IDT), which is linked to worse outcomes and reduced quality of life. On the other hand, ICDs can function as an early warning system for atrial arrhythmias.

PURPOSE: This study aimed to predict which patients are at risk of IDT and who develop atrial high-rate episodes (AHRE) by investigating pre-implant clinical parameters.

METHODS

Patients who received an ICD with an atrial lead between 2010 and 2019 were included in a prospective registry.

RESULTS

Over 5.3 ± 3.0 years, 136 of 413 patients received appropriate device therapy, and 36 patients received IDT. Univariate cox regression analyses on 40 parameters were performed, followed by forward multivariate cox regression. The best predictive model (Harrell's C-index 0.785) included secondary prevention ICD, ischemic CMP (iCMP), CMP not classified as ischemic, hypertrophic or dilated (uCMP), and diuretic use as risk factors, with mineralocorticoid receptor-antagonists (MRA) use and diabetes as protective factors. Surprisingly, AF was not a predictor of IDT. Among 313 patients without prior AF, 136 developed AHRE. Similar cox regressions predicted AHRE development, resulting in a model (Harrell's C-index 0.663) based on age, left ventricular ejection fraction (LVEF), hypertrophic CMP (hCMP), family history of cardiovascular disease (CVD), and hypercholesterolemia.

CONCLUSION

This study identified six factors that influence the risk of IDT, and five other factors as risk factors for developing AHRE. Pre-implant assessment of these variables can help to better inform patients of the potential benefits and risks.

Для цитирования: Huntelaar Marthe J, Hopman Luuk H G A, van der Lingen Anne-Lotte C J, Rijnierse Mischa T, Kemme Michiel J B, Allaart Cornelis P, van Halm Vokko P. Predictors of Atrial High-Rate Episodes and Inappropriate Device Therapy in Implantable Cardioverter Defibrillators.. Pacing and clinical electrophysiology : PACE. 2025. DOI: 10.1111/pace.70094.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.