MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3389/fcvm.2025.1558034

Медицинская библиотека · Frontiers in cardiovascular medicine · 2025

Evaluation of fetal cardiac morphology and function in hypertensive disorders of pregnancy using Fetal HQ technology combined with uterine artery ultrasound parameters.

Wang Lu, Fu Xinghui, Ren Xiaoyu, Guo Yu, Zhou Haixia, Yue Hongli, Song Chunjing, Zhang Danhua, Li Gang, Li Wenrui, Zhang Pengjie

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

Hypertensive disorders of pregnancy (HDP) significantly affect both maternal and fetal health, with uterine artery hemodynamic parameters playing a critical role in assessing fetal well-being, though they do not provide early insights into fetal cardiac function. Fetal Heart Quantification (Fetal HQ) technology offers a non-invasive, highly accurate method for evaluating fetal heart morphology and function, making it a valuable tool for assessing the impact of HDPs on fetal cardiac health.

METHODS

This study investigates fetal heart function and morphology in hypertensive disorders of pregnancy (HDPs) using fetal heart quantification (HQ) technology combined with uterine artery ultrasound parameters. A total of 70 normal fetuses and 59 fetuses with HDPs were included, with 30 cases showing normal and 29 cases showing abnormaluterine artery blood flow patterns. Uterine artery hemodynamic parameters (PI, RI, S/D) and fetal echocardiographic parameters (FRAC, FS, GLS, EF, 4CVCirc, GSI) were assessed.

RESULTS

Results showed that in the HDP group with abnormal uterine artery blood flow, PI, RI, and S/D were significantly higher than in both the control and HDP groups with normal blood flow (P < 0.05). Right ventricular function, including FRAC, GLS, and FS, was significantly decreased in the HDP group with abnormal blood flow, while 4CVCirc and GSI were significantly different from controls. Left ventricular function showed no significant differences. The area under the ROC curve for predicting fetal heart morphology and function via multiple right ventricular parameters was 0.901, and 0.825 for right heart function.

CONCLUSION

These findings suggest that the fetal right ventricle is more sensitive to hemodynamic changes in HDP pregnancies, with right heart functional and morphological indicators potentially serving as predictive markers.

Для цитирования: Wang Lu, Fu Xinghui, Ren Xiaoyu, Guo Yu, Zhou Haixia, Yue Hongli, Song Chunjing, Zhang Danhua, Li Gang, Li Wenrui, Zhang Pengjie. Evaluation of fetal cardiac morphology and function in hypertensive disorders of pregnancy using Fetal HQ technology combined with uterine artery ultrasound parameters.. Frontiers in cardiovascular medicine. 2025. DOI: 10.3389/fcvm.2025.1558034.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.