MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ijsu.2014.01.025

Медицинская библиотека · International journal of surgery (London, England) · 2014

A retrospective study evaluating the use of Permacol™ surgical implant in incisional and ventral hernia repair.

Chand Bipan, Indeck Matthew, Needleman Bradley, Finnegan Matthew, Van Sickle Kent R, Ystgaard Brynjulf, Gossetti Francesco, Pullan Rupert D, Giordano Pasquale, McKinley Aileen

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

The outcome of incisional and ventral hernia repair depends on surgical technique, patient, and material. Permacol™ surgical implant (crosslinked porcine collagen) has been used for over a decade; however, there are few data on outcomes. This study is the largest retrospective multinational study to date to evaluate outcomes with Permacol™ surgical implant in the repair of incisional and ventral hernias.

METHODS

Data were collected retrospectively on 343 patients treated for 213 incisional and 130 ventral hernias. Data evaluated included patient demographics, wound classification, surgical technique, morbidity, and recurrence rates.

RESULTS

Median follow-up time was 649 days (max: 2857), median age 57 years (range 23-91), and BMI 32 kg/m(2) (range 17.6-77.8). Two or more comorbidities were present in 70% of patients. Open surgery was performed in 220 (64%) patients. Permacol™ surgical implant was used as an underlay (250), sublay (39), onlay (37), or inlay (17). Surgical techniques included component separation (89; 25.9%), modified Stoppa technique (197; 57.4%), and Rives-Stoppa (17; 5.0%). CDC Surgical Wound Classification was Class I (190), Class II (103), Class III (28), and Class IV (22). Complications were seen in 40.5% (139) of the patients, with seroma (19%) and wound infection (15%) as the most common. Mesh removal occurred in 1 (0.3%) patient. Kaplan-Meier analysis demonstrated that the probabilities for hernia recurrence at one, two, and three years were 5.8%, 16.6%, and 31.0%, respectively.

CONCLUSIONS

Permacol™ surgical implant was shown to be safe with relatively low rates of hernia recurrence.

CLINICAL TRIAL REGISTRATION NUMBER: NCT01214252 (http://www.clinicaltrials.gov).

Для цитирования: Chand Bipan, Indeck Matthew, Needleman Bradley, Finnegan Matthew, Van Sickle Kent R, Ystgaard Brynjulf, Gossetti Francesco, Pullan Rupert D, Giordano Pasquale, McKinley Aileen. A retrospective study evaluating the use of Permacol™ surgical implant in incisional and ventral hernia repair.. International journal of surgery (London, England). 2014. DOI: 10.1016/j.ijsu.2014.01.025.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.