RAFT-USENet: A Unified Network for Accurate Axial and Lateral Motion Estimation in Ultrasound Elastography Imaging.

Majumder Sharmin, Islam Md Tauhidul, Righetti Raffaella

СтатьяПоддержка исследования: вне правительства СШАПоддержка правительства СШАПеревод в очереди

Аннотация

High-quality motion estimation is essential in ultrasound elastography (USE) for evaluating tissue mechanical properties and detecting abnormalities. Traditional methods, such as speckle tracking and regularized optimization, face challenges including noise, oversmoothing of displacements and prolonged runtimes. Recent efforts have explored optical flow-based convolutional neural networks (CNNs). However, current approaches face, at least, one of the following limitations: 1) reliance on tissue incompressibility assumption, which compromises data fidelity and can introduce large errors; 2) dependence on ground truth displacement data for supervised CNN methods; 3) use of a regularizer not aligned with tissue physics by relying on first-order displacement derivatives only; 4) use of a L2-norm regularizer that oversmoothes motion estimates; and 5) substantially large sampling size, increasing computational and memory demands, especially for classical methods. In this paper, we develop RAFT-USENet, a physics-informed, unsupervised neural network to estimate both axial and lateral displacements. We design RAFT-USENet by substantially modifying the optical flow RAFT network to adapt it to high-frequency USE data. Extensive validation using simulation, phantom and in vivo data demonstrates that RAFT-USENet significantly outperforms existing methods, with normalized cross-correlation values of 0.94, 0.88, and 0.82 in simulation, breast phantom and in vivo datasets, respectively, compared to 0.79-0.88, 0.76-0.85, and 0.69-0.81 for the competing methods. Additionally, RAFT-USENet reduces computational time by 1.5-150 times compared to existing methods. These results suggest that RAFT-USENet may be a potentially reliable and accurate tool for clinical elasticity imaging applications.

Для цитирования: Majumder Sharmin, Islam Md Tauhidul, Righetti Raffaella. RAFT-USENet: A Unified Network for Accurate Axial and Lateral Motion Estimation in Ultrasound Elastography Imaging.. IEEE journal of biomedical and health informatics. 2025. DOI: 10.1109/jbhi.2025.3536786.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.