MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ijgo.70597

Медицинская библиотека · International journal of gynaecology and obstetrics: the official organ of the International Federation of Gynaecology and Obstetrics · 2025

Factors affecting the umbilical artery Doppler reference values in the second and third trimesters.

Rahimi Sophia, Kingdom John C, Vayenas Arietta, Stratulat Vasilica, Melamed Nir

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To explore the contribution of selected methodological factors to the heterogeneity in published umbilical artery pulsatility index (UA-PI) reference charts.

METHODS

Cross-sectional study of uncomplicated singleton pregnancies that underwent assessment of UA Doppler at a single center. We explored the effects of the cohort characteristics (parity and estimated fetal weight [EFW] centile cut-off) and the statistical modeling approach used to construct the UA-PI centile reference charts.

RESULTS

25 069 UA-PI measurements from 12 394 patients were analyzed. UA-PI centile values decreased as the minimal EFW centile inclusion cut-off of the study cohort increased. Interpretation of UA-PI using charts constructed from fetuses with EFW > 25th or 50th centiles resulted in a higher proportion of examinations with UA-PI > 95th centile compared with the chart based on fetuses with EFW⟩10th centile (11.5% and 13.2% versus 10.6% of the subgroup of small-for-gestational-age fetuses, respectively, P < 0.001). In contrast, parity and the statistical method used to construct the chart had minimal impact on the UA-PI centile reference charts. Considerable heterogeneity was identified among published UA-PI reference charts.

CONCLUSION

Variation in the distribution of EFW centiles across the populations used to construct the UA-PI reference chart may contribute to the heterogeneity observed in published charts.

Для цитирования: Rahimi Sophia, Kingdom John C, Vayenas Arietta, Stratulat Vasilica, Melamed Nir. Factors affecting the umbilical artery Doppler reference values in the second and third trimesters.. International journal of gynaecology and obstetrics: the official organ of the International Federation of Gynaecology and Obstetrics. 2025. DOI: 10.1002/ijgo.70597.