MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12968-020-00608-0

Медицинская библиотека · Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2020

4D flow cardiovascular magnetic resonance for monitoring of aortic valve repair in bicuspid aortic valve disease.

Lenz Alexander, Petersen Johannes, Riedel Christoph, Weinrich Julius M, Kooijman Hendrik, Schoennagel Bjoern P, Adam Gerhard, von Kodolitsch Yskert, Reichenspurner Hermann, Girdauskas Evaldas, Bannas Peter

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Aortic valve repair has become a treatment option for adults with symptomatic bicuspid (BAV) or unicuspid (UAV) aortic valve insufficiency. Our aim was to demonstrate the feasibility of 4D flow cardiovascular magnetic resonance (CMR) to assess the impact of aortic valve repair on changes in blood flow dynamics in patients with symptomatic BAV or UAV.

METHODS

Twenty patients with adult congenital heart disease (median 35 years, range 18-64; 16 male) and symptomatic aortic valve regurgitation (15 BAV, 5 UAV) were prospectively studied. All patients underwent 4D flow CMR before and after aortic valve repair. Aortic valve regurgitant fraction and systolic peak velocity were estimated. The degree of helical and vortical flow was evaluated according to a 3-point scale. Relative flow displacement and wall shear stress (WSS) were quantified at predefined levels in the thoracic aorta.

RESULTS

All patients underwent successful aortic valve repair with a significant reduction of aortic valve regurgitation (16.7 ± 9.8% to 6.4 ± 4.4%, p < 0.001) and systolic peak velocity (2.3 ± 0.9 to 1.9 ± 0.4 m/s, p = 0.014). Both helical flow (1.6 ± 0.6 vs. 0.9 ± 0.5, p < 0.001) and vortical flow (1.2 ± 0.8 vs. 0.5 ± 0.6, p = 0.002) as well as both flow displacement (0.3 ± 0.1 vs. 0.25 ± 0.1, p = 0.031) and WSS (0.8 ± 0.2 N/m2 vs. 0.5 ± 0.2 N/m2, p < 0.001) in the ascending aorta were significantly reduced after aortic valve repair.

CONCLUSIONS

4D flow CMR allows assessment of the impact of aortic valve repair on changes in blood flow dynamics in patients with bicuspid aortic valve disease.

Для цитирования: Lenz Alexander, Petersen Johannes, Riedel Christoph, Weinrich Julius M, Kooijman Hendrik, Schoennagel Bjoern P, Adam Gerhard, von Kodolitsch Yskert, Reichenspurner Hermann, Girdauskas Evaldas, Bannas Peter. 4D flow cardiovascular magnetic resonance for monitoring of aortic valve repair in bicuspid aortic valve disease.. Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance. 2020. DOI: 10.1186/s12968-020-00608-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.