MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/jaoacint/qsac141

Медицинская библиотека · Journal of AOAC International · 2023

Redox-Based Colorimetric Sensor for the Selective Determination of Ascorbic Acid in Fixed-Dose Combination Tablets.

El-Malla Samah F, Mansour Fotouh R, Elattar Rehab H, Kamal Amira H

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Ascorbic acid (ASC; vitamin C) is a weak chromophore, so its presence cannot be determined directly by spectrophotometry.

OBJECTIVE

This work aims to develop and validate a simple and ecofriendly analytical method for the determination of ASC concentration based on the reaction of ASC with the metal complex, ferric salicylate.

METHODS

The visible absorbance of ferric salicylate was found to be inversely proportional to the concentration of ASC. The possible mechanism of the reaction between ASC and ferric salicylate was investigated: ferric salicylate was found to be reduced by ASC under the applied experimental conditions. Different parameters that may affect the reaction were also investigated: ferric salicylate concentration, pH, ionic strength, and the time of reaction. The optimum concentration of ferric salicylate was found to be 1000 µM and the optimum pH was 5.5. The developed method was validated according to International Conference on Harmonization (ICH) guidelines.

RESULTS

The linearity range of the developed method was 5-70 µg/mL and the correlation coefficient was 0.9994. The limits of detection and quantitation were 0.38 µg/mL and 1.16 µg/mL, respectively. The method was successfully applied to the determination of ASC concentration in commercial Ruta-C60® tablets. The mean recovery ± standard deviation was found to be 101.10 ± 0.70%. The results were statistically compared to those obtained by a reported HPLC method. Good agreement was observed.

CONCLUSION

The developed method is simple, fast, cost-effective, and suitable for routine pharmaceutical analysis of ASC.

HIGHLIGHTS: The developed method is more sensitive than the other spectrophotometric methods reported for determination of ASC.

Для цитирования: El-Malla Samah F, Mansour Fotouh R, Elattar Rehab H, Kamal Amira H. Redox-Based Colorimetric Sensor for the Selective Determination of Ascorbic Acid in Fixed-Dose Combination Tablets.. Journal of AOAC International. 2023. DOI: 10.1093/jaoacint/qsac141.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.