AIM OF THE STUDY: CSF1R-related disorder (CSF1R-RD) is a rare, autosomal dominant microgliopathy characterized by leukoencephalopathy. While extrapyramidal symptoms are common, the underlying integrity of the presynaptic dopaminergic system in these patients remains poorly understood. The aim of our study was to analyze dopamine transporter availability using single-photon emission computed tomography (SPECT) 123I-ioflupane in patients with CSF1R mutations to differentiate the pathophysiology of their parkinsonism.

MATERIAL AND

METHODS

We conducted a retrospective review of 112 electronic medical charts from a large tertiary referral medical center. Four patients (3.6%) with CSF1R variants underwent SPECT 123I-ioflupane imaging. Clinical data, MRI findings, and genetic pathogenicity were assessed.

RESULTS

SPECT 123I-ioflupane results were normal i n 3 patients, despite t he presence of parkinsonian symptoms, i ncluding tremor, rigidity, and bradykinesia. The only patient with an abnormal SPECT 123I-ioflupane result was a 70-year-old with a pathogenic CSF1R c.1924C > T, p.Gln642* variant and a clinical phenotype of classic Parkinson disease.

CONCLUSIONS AND CLINICAL IMPLICATIONS: Parkinsonism in CSF1R-RD may present with a normal SPECT 123I-ioflupane results, suggesting that motor deficits arise from white matter degradation and disrupted connectivity rather than primary nigrostriatal loss.

Для цитирования: Milanowski Łukasz, Young Jason R, Grill Stephen, Savica Rodolfo, Wszolek Zbigniew K. Single-photon emission computed tomography 123I-ioflupane imaging in CSF1R mutation carriers.. Neurologia i neurochirurgia polska. 2026. DOI: 10.5603/pjnns.111575.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.