m+Medelevator.RU
← Поиск публикаций
Journal of analytical toxicology · 2018

Time-Dependent Postmortem Redistribution of Opioids in Blood and Alternative Matrices.

Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Brockbals Lana, Staeheli Sandra N, Gascho Dominic, Ebert Lars C, Kraemer Thomas, Steuer Andrea E

Аннотация

Forensic postmortem case interpretation can be challenging, in particular due to postmortem redistribution (PMR) phenomena. Recent studies have shown that computed tomography (CT)-guided collection of biopsy samples using a robotic arm (virtobot) provides a valuable tool for systematic studies on time-dependent PMR. Utilizing this strategy, several cases involving opioid use such as methadone, fentanyl, tramadol, codeine, oxycodone and hydrocodone were evaluated for time-dependent concentration changes and potential redistribution mechanisms. Upon admission to the institute (t1), blood (femoral and right ventricle heart blood) and tissue biopsy samples (lung, kidney, liver, spleen, thigh muscle and adipose tissue) were collected utilizing CT-guided biopsy. Approximately 24 h later (t2; mean 28 ± 15 h), during the autopsy, samples from the same body regions were collected manually and in addition brain tissue, gastric content, urine and left ventricle heart blood. Analysis was conducted with liquid chromatography tandem mass spectrometry. Significant time-dependent methadone concentration increases in femoral blood (pB) indicate the occurrence of PMR, however, ultimately not relevant for forensic interpretation. The main metabolite of methadone, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP), showed a less significant trend for PMR. Redistribution by passive diffusion along the muscle-to-pB concentration gradient seems likely for methadone, but not for EDDP. Results for fentanyl suggest extensive PMR. Other opioids such as tramadol, codeine, hydrocodone and oxycodone showed no consistent trend for significant PMR. Overall, CT-guided biopsy sampling proved to be a valuable tool for the investigation of PMR mechanisms.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты