MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/14670100.2016.1177261

Медицинская библиотека · Cochlear implants international · 2016

Cochlear implantation in a subject with a narrow facial recess: Importance of preoperative radiological findings.

Emal Tahir

Клинический случайСтатьяПеревод в очереди

Аннотация

OBJECTIVE

This case report aims to emphasize the importance of preoperative computed tomography to evaluate the anatomy of the facial recess (FR) in order to prevent complications during cochlear implantation (CI) and to discuss alternative surgical approaches for the management of a narrow FR. Failure to notice this anomaly may result in facial nerve (FN) injury or inability to complete CI.

CASE PRESENTATION: A 50-year-old female with bilateral sensorineural hearing loss presented for CI. High-resolution CT (HRCT) demonstrated a narrow FR; specifically the space between the vertical segment of the FN and external auditory canal (EAC) was narrow. A section of the EAC was removed to obtain adequate exposure and was repaired with a cartilage graft following CI.

CONCLUSION

CI surgery may be difficult in patients with a narrow FR. Such surgical difficulty could be avoided if cochlear implant surgeons have adequate preoperative radiological imaging to evaluate the anatomy of the temporal bone. HRCT is the only modality that can detect this abnormality preoperatively. If the surgeon identifies this abnormality on preoperative HRCT, an alternative surgical technique could be used.

Для цитирования: Emal Tahir. Cochlear implantation in a subject with a narrow facial recess: Importance of preoperative radiological findings.. Cochlear implants international. 2016. DOI: 10.1080/14670100.2016.1177261.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.