MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ejogrb.2011.04.027

Медицинская библиотека · European journal of obstetrics, gynecology, and reproductive biology · 2011

Vaginal prolapse repair using the Prolift kit: a registry of 100 successive cases.

Simon Marie, Debodinance Philippe

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

To evaluate anatomical, functional outcomes and complications inherent to the treatment of pelvic organ prolapse by implantation of polypropylene mesh, using the Prolift kit.

MATERIALS AND

METHODS

Single-center observational study of 100 successive patients enrolled in a registry, who underwent Prolift prolapse repair. Data on prior treatments, associated procedures and per- and post-operative complications were collected and the patients were seen after 2, 6 and 12 months. Anatomical outcomes were assessed using the International Continence Society Pelvic Organ Prolapse Quantification (ICS POP-Q) system. Function was assessed in terms of urinary and digestive problems, and impact on sex life. Failure was defined as relapse of POP-Q Grade 2 or more.

RESULTS

Of the 100 patients, 32 had an anterior, 14 a posterior, 54 a total Prolift; 53 had concomitant urinary incontinence surgery. At 6 and 12 months respectively, 8% and 12% of the patients were lost to follow-up. Mean operating time was 39.8 min. With respect to peri-operative complications, there was no bladder or rectal damage but three patients experienced bleeding (≥ 300 ml) without needing transfusion. POP-Q Grades before surgery were: Grades III-IV cystocele in 65.7% of the anterior Prolift patients; Grades II-III rectocele in the posterior; and 77.8% of total were Grade III and 11.1% Grade IV. The incidence of recurrence was 3.6% at Month 6 and 10.2% at Month 12. Significant (p<0.05) improvements were seen in median scores for the various POP-Q items. With respect to functional problems, stress urinary incontinence was cured in 92% of the patients but 7.7% reported new-onset urinary incontinence after one year. One case of vaginal exposure after one year was observed and major or symptomatic mesh retraction was observed in 8%. New-onset dyspareunia was reported by 11.1% of the patients.

CONCLUSIONS

These results confirm the feasibility of using the Prolift kit in the repair of prolapse via a vaginal approach and the low per- and post-operative morbidity associated with that technique. Nevertheless, longer-term evaluation is required to confirm the results.

Для цитирования: Simon Marie, Debodinance Philippe. Vaginal prolapse repair using the Prolift kit: a registry of 100 successive cases.. European journal of obstetrics, gynecology, and reproductive biology. 2011. DOI: 10.1016/j.ejogrb.2011.04.027.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.