MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ctarc.2025.100865

Медицинская библиотека · Cancer treatment and research communications · 2025

Diagnostic performance of digital breast tomosynthesis (DBT) versus digital mammography (DM) in a population clinically referred for breast imaging - a retrospective cohort study.

Noguchi Naomi, Boroumand Farzaneh, Bell Katy, Pooley Margaret, Zeng Aileen, Arnold Lauren, Teixeira-Pinto Armando, Houssami Nehmat

СтатьяСравнительное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To compare the performance of Digital Breast Tomosynthesis (DBT) with Digital Mammography (DM) in patients clinically referred for breast imaging.

METHODS

Diagnostic performance of DBT (in 2016, after transition to DBT) was compared with DM (in 2011, before the transition) in consecutively referred patients (N = 10,742 exams). Reference standard was outcomes from all tests including histopathology and clinical review within the same year. Primary outcome was area under receiver operating characteristic curve (AUC-ROC).

RESULTS

Cancer rates did not differ between DBT (1.72 % (CI 1.38-2.15 %)) and DM (1.71 % (CI 1.40-2.08 %)). AUC-ROC was similar for DBT (0.91 (CI 0.87-0.95)) and DM (CI 0.91 (0.88-0.95)). Abnormal interpretation rate for DBT was 2.83 % (CI 2.38-3.36 %) and for DM it was 2.17 % (CI 1.82-2.58 %), and the biopsy rate for DBT was 8.2 % (CI 7.4-9.0 %) and for DM it was 9.9 % (CI 9.1-10.6 %)). In patients with dense breasts (vs overall cohort) AUC-ROC and sensitivity were lower for both DM and DBT. Within this subgroup, AUC-ROC for DBT was 0.90 (CI 0.84-0.95) and for DM it was 0.85 (CI 0.79-0.92), sensitivity was 78.2 % (CI 65.0-88.2 %) for DBT and 64.8 % (CI 50.6-77.3 %) for DM, and ultrasound was accurate whether it was used with DBT (AUC-ROC 0.95 (CI 0.91 - 0.99)) or DM (AUC-ROC 0.95 (CI 0.90 - 0.99))

CONCLUSION

In clinically referred patients, diagnostic accuracy and diagnostic yield were similar between DBT and DM. DBT may have a higher abnormal interpretation rate but a lower biopsy rate. DBT may be more accurate than DM in dense breasts.

Для цитирования: Noguchi Naomi, Boroumand Farzaneh, Bell Katy, Pooley Margaret, Zeng Aileen, Arnold Lauren, Teixeira-Pinto Armando, Houssami Nehmat. Diagnostic performance of digital breast tomosynthesis (DBT) versus digital mammography (DM) in a population clinically referred for breast imaging - a retrospective cohort study.. Cancer treatment and research communications. 2025. DOI: 10.1016/j.ctarc.2025.100865.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.