MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.resuscitation.2016.04.001

Медицинская библиотека · Resuscitation · 2016

Better prognostic value with combined optic nerve sheath diameter and grey-to-white matter ratio on initial brain computed tomography in post-cardiac arrest patients.

Chae Minjung Kathy, Ko Eunsil, Lee Jeong Hoon, Lee Tae Rim, Yoon Hee, Hwang Sung Yeon, Cha Won Chul, Shin Tae Gun, Sim Min Seob, Jo Ik Joon, Song Keun Jeong, Rhee Joong Eui, Jeong Yeon Kwon

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

AIM: We aimed to evaluate the prognostic value of optic nerve sheath diameter (ONSD) and grey-to-white matter (GWR) either alone or in combination in patients treated with targeted temperature management (TTM) after cardiac arrest (CA).

METHODS

We conducted a retrospective single centre study of post cardiac arrest patients treated with TTM. ONSD and GWR on brain computed tomography (CT) was measured by two emergency physicians. We analysed the prognostic performance and cut offs of GWR and ONSD, singly and in combination in predicting poor neurologic outcome (CPC 3-5).

RESULTS

Of the 119 patients studied, 74 patients showed poor outcome. The combination of ONSD and GWR significantly (p=0.002) improved prognostic performance (AUROC 0.67, 95% CI: 0.58-0.76, p<0.001) in predicting poor neurologic outcomes rather than each ONSD (AUROC 0.59, 95% CI: 0.50-0.68, p=0.08) or GWR (AUROC 0.65, 95% CI: 0.56-0.74, p=0.002) alone. A combined cut off of 'GWR and ONSD (1.16 and 4.9)' and 'GWR or ONSD (1.13 or 6.5)' improved the sensitivity for predicting poor outcome while maintaining high specificity compared to GWR alone.

CONCLUSION

The combination of ONSD and GWR yielded improved prognostic value for predicting poor neurologic outcomes in post cardiac arrest patients treated with TTM.

Для цитирования: Chae Minjung Kathy, Ko Eunsil, Lee Jeong Hoon, Lee Tae Rim, Yoon Hee, Hwang Sung Yeon, Cha Won Chul, Shin Tae Gun, Sim Min Seob, Jo Ik Joon, Song Keun Jeong, Rhee Joong Eui, Jeong Yeon Kwon. Better prognostic value with combined optic nerve sheath diameter and grey-to-white matter ratio on initial brain computed tomography in post-cardiac arrest patients.. Resuscitation. 2016. DOI: 10.1016/j.resuscitation.2016.04.001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.