MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3944/aott.2009.366

Медицинская библиотека · Acta orthopaedica et traumatologica turcica · 2009

[Evaluation of soft tissue reactions to three nonabsorbable suture materials in a rabbit model].

Esenyel Cem Zeki, Demirhan Mehmet, Kiliçoğlu Onder, Adanir Oktay, Bilgiç Bilge, Güzel Ozlem, Ozsoy Serhat

Аннотация на английскомСтатьяПеревод в очереди

Аннотация

OBJECTIVES

We evaluated the inflammatory reactions induced by three commonly used nonabsorbable suture materials in a rabbit model.

METHODS

Three suture materials were tested: braided polyester suture (Ethibond), braided blend of polyester and polyethylene suture (FiberWire), and monofilament polypropylene suture (Polypropylene). Thirty-six rabbits were randomly allocated to three suture groups, equal in number. Each suture type was placed bilaterally in the quadriceps muscle, patellar tendon, knee joint capsule, and Achilles tendon. Six animals in each group were sacrificed in the third and sixth weeks. The inflammation induced by each suture was assessed using light microscopy and the width of the inflammation zone (WIZ) was measured.

RESULTS

Ethibond was found to cause the most severe reaction in the muscle and tendon in the third week; in the sixth week, however, it showed the lowest inflammatory reaction in all tissue types. Reaction to Propylene was moderate in the third week, whereas it caused the largest WIZ in all tissue types in the sixth week, such that the eventual size of the WIZ induced by Propylene (6.6 + or - 2.1 mm) was significantly greater than that of Ethibond (1.6 + or - 0.9 mm) in muscle specimens (p<0.05). Except for the largest WIZ seen in joint capsule specimens in the third week, inflammatory reactions associated with FiberWire were low or moderate in all tissue specimens throughout the study. FiberWire was associated with some necrotic areas in two muscle and one tendon specimens.

CONCLUSION

The extent of inflammatory reaction to nonabsorbable suture materials depends on the type of suture material, tissue type, and the duration of postoperative time.

Для цитирования: Esenyel Cem Zeki, Demirhan Mehmet, Kiliçoğlu Onder, Adanir Oktay, Bilgiç Bilge, Güzel Ozlem, Ozsoy Serhat. [Evaluation of soft tissue reactions to three nonabsorbable suture materials in a rabbit model].. Acta orthopaedica et traumatologica turcica. 2009. DOI: 10.3944/aott.2009.366.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.