MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0221-0363(05)81392-7

Медицинская библиотека · Journal de radiologie · 2005

[Can US-guided vacuum-assisted biopsies be an alternative to diagnostic surgery in cases of non-diagnostic core needle biopsy?].

Carpentier E, Maruani A, Michenet P, Bonneau C, Degand P, Lebas P

Аннотация на английскомСтатьяПеревод в очереди

Аннотация

PURPOSE: To assess US-guided vacuum-assisted biopsies in the diagnosis of suspicious sonographic breast lesions after non-diagnostic core needle biopsies (CNB).

PATIENTS AND

METHODS

Retrospective study of 42 females with suspicious breast lesions at US. CNB previously performed were non-diagnostic. Because of the larger sample size, vacuum-assisted biopsies were performed, instead of surgical biopsy.

RESULTS

Vacuum-assisted biopsies showed 32 benign lesions. Histologic examination of the CNB showed non-specific fibrous tissue in 43% of cases as opposed to 7.1% for vacuum-assisted biopsies. The latter provided a more specific diagnosis (mainly fibrocystic breast disease). From a total of 4 lesions that were suspicious at CNB, 3 were diagnosed as malignancies after vacuum-assisted biopsy and one case was a "borderline" lesion. Three additional malignant and three additional borderline lesions were diagnosed on vacuum-assisted biopsies. In 11 cases, surgical excision was performed, and all diagnoses from vacuum-assisted biopsies were confirmed at microscopy, except in one case where it was underestimated (ADH versus DCIS).

CONCLUSION

US-guided vacuum-assisted biopsy is a reliable technique. Because it provides more tissue than CNB, it can be an alternative to diagnostic surgery after non-diagnostic CNB. Indeed, it allows confirmation of the diagnosis and provides a more specific diagnosis of benign lesions. With regards to malignant and borderline lesions, it avoids the risk of false-negative CNB and overlooking carcinomas.

Для цитирования: Carpentier E, Maruani A, Michenet P, Bonneau C, Degand P, Lebas P. [Can US-guided vacuum-assisted biopsies be an alternative to diagnostic surgery in cases of non-diagnostic core needle biopsy?].. Journal de radiologie. 2005. DOI: 10.1016/s0221-0363(05)81392-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.