MedElevator Войти в исследования
← Поиск публикаций

DOI 10.65717/eej.2026.25158

Медицинская библиотека · European endodontic journal · 2026

Evaluation of a Novel Polyether Ether Ketone Activation Tip for Smear Layer Removal.

Peña-Bengoa Fernando, Gonçalves Belladonna Felipe, Abarca Jaime, Steinfort Karin, Caceres Carolina, Moreno Javiera, Ortega Maria Francisca, Gutierrez Yoselyn, Kato Augusto Shoji, Leal Silva Emmanuel João Nogueira

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

This study aimed to evaluate the effectiveness of a polyether ether ketone (PEEK) activation tip in smear layer removal.

MATERIALS AND

METHODS

Fifty maxillary upper incisors were prepared up to a size 50/05 instrument and embedded in tubes filled with heavy-body silicone to create a customised matrix for each specimen. The teeth were removed from the matrices, sectioned longitudinally, and standardised grooves were created at 3, 6, and 9 mm from the apex to delineate the buccal canal wall area for analysis. Specimens were then reassembled, repositioned in their respective matrices, and allocated to the following groups: ultrasonic activation with a PEEK tip, ultrasonic activation with a metallic tip, conventional non-activated irrigation, and 2 control groups (positive and negative). Smear layer removal at each level was evaluated using environmental scanning electron microscopy and scored according to a 4-point scale. Statistical analysis was performed using the Kruskal-Wallis test (P < .05).

RESULTS

Ultrasonic activation with both PEEK and metallic tips significantly enhanced smear layer removal compared to conventional non-activated irrigation at the 3 mm level. At the 6- and 9-mm levels, no significant differences were found between the PEEK and metallic tips; however, both outperformed the conventional method.

CONCLUSION

These findings suggest that ultrasonic activation with PEEK tips is an effective option for smear layer removal, providing results comparable to those achieved with metallic tips across all evaluated canal levels.

Для цитирования: Peña-Bengoa Fernando, Gonçalves Belladonna Felipe, Abarca Jaime, Steinfort Karin, Caceres Carolina, Moreno Javiera, Ortega Maria Francisca, Gutierrez Yoselyn, Kato Augusto Shoji, Leal Silva Emmanuel João Nogueira. Evaluation of a Novel Polyether Ether Ketone Activation Tip for Smear Layer Removal.. European endodontic journal. 2026. DOI: 10.65717/eej.2026.25158.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.