DOI 10.1016/j.ajog.2012.06.007
Preoperative intravascular balloon catheters and surgical outcomes in pregnancies complicated by placenta accreta: a management paradox.
Аннотация
OBJECTIVE
The objective of the study was to compare outcomes between patients who did and did not receive preoperative uterine artery balloon catheters in the setting placenta accreta.
STUDY
DESIGN
This was a retrospective case-control study of patients with placenta accreta from 1990 to 2011.
RESULTS
Records from 117 patients with pathology-proven accreta were reviewed. Fifty-nine patients (50.4%) had uterine artery balloons (UABs) placed preoperatively. The mean estimated blood loss (EBL) was lower (2165 mL vs 2837 mL; P = .02) for the group that had UABs compared with the group that did not. There were more cases with an EBL greater than 2500 mL and massive transfusions of packed red blood cells (>6 units) in the group that did not have UABs. Percreta was diagnosed more often on final pathology in the group with UABs. Surgical times did not differ between the 2 groups. Two patients (3.3%) had complications related to the UABs.
CONCLUSION
Preoperative placement of UABs is relatively safe and is associated with a reduced EBL and fewer massive transfusions compared with a group without UABs.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.