MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.clinbiomech.2015.05.007

Медицинская библиотека · Clinical biomechanics (Bristol, Avon) · 2015

Biomechanical evaluation of a novel suturing scheme for grafting load-bearing collagen scaffolds for rotator cuff repair.

Islam Anowarul, Bohl Michael S, Tsai Andrew G, Younesi Mousa, Gillespie Robert, Akkus Ozan

СтатьяПоддержка NIH: внешняя программаПоддержка правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Currently, there are no well-established suture protocols to attach fully load-bearing scaffolds which span tendon defects between bone and muscle for repair of critical sized tendon tears. Methods to attach load-bearing tissue repair scaffolds could enable functional repair of tendon injuries.

METHODS

Sixteen rabbit shoulders were dissected (New Zealand white rabbits, 1yr. old, female) to isolate the humeral-infraspinatus muscle complex. A unique suture technique was developed to allow for a 5mm segmental defect in infraspinatus tendon to be replaced with a mechanically strong bioscaffold woven from pure collagen threads. The suturing pattern resulted in a fully load-bearing scaffold. The tensile stiffness and strength of scaffold repair were compared with intact infraspinatus and regular direct repair.

FINDINGS: The failure load and displacement at failure of the scaffold repair group were 59.9N (standard deviation, SD=10.7) and 10.3mm (SD=2.9), respectively and matched those obtained by direct repair group which were 57.5N (SD=15.3) and 8.6mm (SD=1.5), (p>0.05). Failure load, displacement at failure and stiffness of both of the repair groups were half of the intact infraspinatus shoulder group.

INTERPRETATION: With the developed suture technique, scaffold repair showed similar failure load, displacement at failure and stiffness to the direct repair. This novel suturing pattern and the mechanical robustness of the scaffold at time zero indicates that the proposed model is mechanically viable for future in vivo studies which has a higher potential to translate into clinical uses.

Для цитирования: Islam Anowarul, Bohl Michael S, Tsai Andrew G, Younesi Mousa, Gillespie Robert, Akkus Ozan. Biomechanical evaluation of a novel suturing scheme for grafting load-bearing collagen scaffolds for rotator cuff repair.. Clinical biomechanics (Bristol, Avon). 2015. DOI: 10.1016/j.clinbiomech.2015.05.007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.