Fang Yiling, Wu Shengquan, Wu Ze, Wang Yibin, Fu Qiangqiang, Miao Yun

Аннотация

This study aimed to develop a smartphone-based analyzer capable of detecting hemoglobin and potassium levels, with clinical validation using a perioperative renal transplant cohort. We implemented azide-methemoglobin and potassium-tetraphenylborate reactions to detect hemoglobin and potassium levels respectively. A smartphone-based system using ambient light sensors and a Phyphox application was used to measure the light intensity changes, with concentrations calculated via calibration curves. 461 hemoglobin measurements and 481 serum potassium test results from 133 patients with end-stage renal disease admitted for pre-transplant evaluation and 51 perioperative renal transplantation patients were analyzed. According to the Bland-Altman analysis, hemoglobin and potassium measurements showing biases of -1.80 g/L (95% limits of agreement: -7.40 to 3.79 g/L) and 0.015 mM (95% limits of agreement: -0.566 to 0.596 mM), respectively. The diagnostic accuracy was acceptable, with overall rates of 86.55% for anemia and 87.73% for dyskalemia. Error grid analysis indicated that 0.40% of hemoglobin values exceeding the ±10.00% limits and 5.81% of potassium values surpassing the ±0.05 mM limits. The analyzer demonstrated remarkable efficiency, achieving median turnaround times of 2 and 29 min for hemoglobin and potassium, respectively. Additionally, we analyzed 221 critical laboratory values from pre-transplant and post-transplant patients. The analysis identified electrolytes and acid-base disorders as the second most frequent pre-transplant and most frequent post-transplant critical alerts and dyskalemia predominated within this category. Similarly, anemia predominated within the pre-transplant and post-transplant hematologic emergencies. In conclusion, the analyzer offers advantages including portability, accuracy, stability and rapidity, and demonstrates significant clinical value for renal transplant recipients.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты