Clinical Outcomes and Use of Implantable Cardioverter-Defibrillator in Ischemic Heart Failure Patients with Reduced Ejection Fraction: A Retrospective Observational Study.

Cho Kyung Hoon, Lee Ki Hong, Lee Yong-Kyu, Oh Seok, Lim Yongwhan, Ahn Joon Ho, Lee Seung Hun, Hyun Dae Young, Kim Min Chul, Sim Doo Sun, Hong Young Joon, Kim Ju Han, Ahn Youngkeun, Lee Jang Hoon, Hahn Joo-Yong, Kim Yu-Ri, Yoon Nam Sik, Park Hyung Wook, Kim Weon, Jeong Myung Ho, Korea Acute Myocardial Infarction Registry (KAMIR)-National Institutes of Health (NIH)-Implantable Cardioverter Defibrillators (ICD) Investigators

СтатьяПеревод в очереди

Аннотация

Limited data exist regarding the real-world practices and clinical outcomes in patients with ischemic heart failure with reduced left ventricular ejection fractions (LVEFs). Using nationwide registry data from South Korea, we aimed to investigate long-term outcomes and clinical practices, especially implantable cardioverter defibrillators (ICDs) implantation, in patients with reduced LVEFs at least 40 days after acute myocardial infarction (AMI). Of 13,056 patients with AMI between 2011 and 2015, we analyzed 350 (median age, 66 years [interquartile range, 56-75]) who had LVEFs <40% on follow-up transthoracic echocardiogram 40 days after the index event. The primary outcome was cardiac-cause mortality at 3 years. Secondary outcomes comprised major cardiovascular events as well as outcomes defined by the use of ICDs, cardiac resynchronization therapy defibrillators (CRT-Ds), and electrophysiology studies. Among 350 patients, 39 (11.1%) died from cardiac causes during 3 years of follow-up. Eleven (3.1%) were hospitalized for ventricular tachycardia. The rate of ICD or CRT-D implantation up to 3 years was 5.7% (20/350). Cox time-to-event analysis revealed older age, LVEF <30%, diabetes mellitus, and previous MI or revascularization as positively associated with cardiac death, whereas the use of statins and body weight <67 kg were negatively associated. This nationwide Korean registry demonstrated that only 5.7% of patients who had reduced LVEFs after 40 days of AMI underwent ICD implantations over 3 years. Considering the high mortality, concerted efforts are needed to improve clinical outcomes for patients who may have been candidates for ICD implantation.

Для цитирования: Cho Kyung Hoon, Lee Ki Hong, Lee Yong-Kyu, Oh Seok, Lim Yongwhan, Ahn Joon Ho, Lee Seung Hun, Hyun Dae Young, Kim Min Chul, Sim Doo Sun, Hong Young Joon, Kim Ju Han, Ahn Youngkeun, Lee Jang Hoon, Hahn Joo-Yong, Kim Yu-Ri, Yoon Nam Sik, Park Hyung Wook, Kim Weon, Jeong Myung Ho, Korea Acute Myocardial Infarction Registry (KAMIR)-National Institutes of Health (NIH)-Implantable Cardioverter Defibrillators (ICD) Investigators. Clinical Outcomes and Use of Implantable Cardioverter-Defibrillator in Ischemic Heart Failure Patients with Reduced Ejection Fraction: A Retrospective Observational Study.. Chonnam medical journal. 2026. DOI: 10.4068/cmj.2026.62.2.55.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.