MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/neuros/nyz396

Медицинская библиотека · Neurosurgery · 2020

Single-Arm, Open-Label, Multicenter Study to Evaluate the Safety and Performance of Dura Sealant Patch in Reducing Cerebrospinal Fluid Leakage Following Elective Cranial Surgery: The ENCASE Trial Study Protocol.

van Doormaal Tristan P C, Germans Menno R, Sie Mariska, Brouwers Bart, Fierstra Jorn, Depauw Paul R A M, Robe Pierre A, Regli Luca

Протокол клинического исследованияСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Cerebrospinal fluid (CSF) leakage is one of the most common neurosurgical complications, occurring in 4% to 32% of surgical cases, with a higher incidence in complicated skull base surgery, intradural spine surgery, and the surgery of the posterior fossa. Our group developed a Dural Sealant Patch (DSP) for watertight dural closure after cranial surgery.

OBJECTIVE

To clinically study for the first time the safety and performance of the DSP as a means of reducing CSF leakage in patients undergoing elective cranial intradural surgery with a dural closure procedure.

METHODS

We will conduct an open-label, single-arm, multicenter study with a 360 d (12 mo) follow-up. A total of 40 patients will be enrolled at 3 sites. The primary endpoint is a combination of occurrences of one of the following events: postoperative percutaneous CSF leakage, intraoperative leakage at 20 cm H2O, or postoperative wound infection. The secondary endpoints are pseudomeningocele and thickness of dura + DSP.

EXPECTED OUTCOMES: Not more than 3 patients will meet the primary endpoint suggesting safety and efficacy.

DISCUSSION: As a next step, a randomized controlled trial against the best current practice will follow to evaluate if DSP reduces CSF leakage while its safety is noninferior.

Для цитирования: van Doormaal Tristan P C, Germans Menno R, Sie Mariska, Brouwers Bart, Fierstra Jorn, Depauw Paul R A M, Robe Pierre A, Regli Luca. Single-Arm, Open-Label, Multicenter Study to Evaluate the Safety and Performance of Dura Sealant Patch in Reducing Cerebrospinal Fluid Leakage Following Elective Cranial Surgery: The ENCASE Trial Study Protocol.. Neurosurgery. 2020. DOI: 10.1093/neuros/nyz396.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.