Objective assessment of dermatitis following post-operative radiotherapy in patients with breast cancer treated with breast-conserving treatment.
Аннотация
PURPOSE: To evaluate radiation dermatitis objectively in patients with breast cancer who had undergone post-operative radiotherapy after breast-conserving surgery.
PATIENTS AND
METHODS
Skin color (L*, a*, and b* values) and moisture analyses were performed for both breasts (before, after, 1 month, 6 months, and 1 year after radiotherapy) to examine irradiated and non-irradiated skin divided into four quadrants in 118 patients. These patients underwent breast conservative surgery followed by 50 Gy/25 fractions (median) of radiotherapy with or without boost irradiation (10 Gy/5 fractions).
RESULTS
L*, a*, and moisture values were changed by irradiation and maximized at completion or 1 month after radiotherapy. One year after radiotherapy, the skin color had returned to the range observed prior to radiotherapy. However, moisture did not return to previous values even 1 year after treatment. The lateral upper side (quadrant C) showed greater changes than other quadrants in the L* value (darker) at the end of radiotherapy. The Common Toxicity Criteria version 3 scores were found to correlate well with a* and L* values at the completion and 1 month after radiotherapy. Boost radiotherapy intensified reddish and darker color changes at the completion of radiotherapy, while chemotherapy did not intensify the skin reaction caused by radiotherapy.
CONCLUSION
Moisture impairment as a result of irradiation lasts longer than color alterations. Objective assessments are useful for analyzing radiation dermatitis.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.