Subcutaneous anchoring device for securement of tunneled hemodialysis catheters: A first retrospective multicenter case series.

Guzzi Francesco, Fumagalli Giordano, Guenzi Lorenzo, Biuso Marica, Campolo Gesualdo, Migliori Massimiliano, De Pietro Stefano

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

BACKGROUND

Subcutaneous Anchor Securement System (SASS) are increasingly used for stabilization of vascular access devices. For many hemodialysis (HD) patients tunneled central venous catheters (t-CVC) are the last vascular access option and their unplanned replacement results in complex procedures and increased costs. Nevertheless, accidental dislodgment of hemodialysis t-CVC is a frequent occurrence in clinical practice. We here describe our first experience with SASS utilization in this unexplored setting.

METHODS

Between July 2022 and September 2023, we applied a SASS (SecurAcath®) to newly placed Tesio t-CVC in two HD centers. Patients were routinely monitored as per center standard protocol for accidental t-CVC dislodgment, tip migration, t-CVC dysfunction, early and late SASS-related complications, until a censoring event or the end of follow-up (December 2023) occurred. Data were retrospectively collected by two Authors per center, cross-checked, and analyzed with descriptive statistics in a case series.

RESULTS

Twenty-four Tesio t-CVC were included in the analysis. Among the entire cohort, the SASS (each with the corresponding t-CVC) were maintained for a total of 5.324 CVC-days. Median single device length of follow-up was 188 (144-276) days. Complete accidental dislodgment with cuff exposure and need for t-CVC replacement was never observed. One bleeding episode was reported among early complications. Infection incidence rate was 0.56 per 1.000 CVC-days and 71% of Tesio t-CVC with their SASS were still in use at the end of follow-up.

CONCLUSIONS

This is the first report of the use of SASS in HD t-CVC. In our experience, SecurAcath® was safe and effective for stabilization of Tesio t-CVC.

Для цитирования: Guzzi Francesco, Fumagalli Giordano, Guenzi Lorenzo, Biuso Marica, Campolo Gesualdo, Migliori Massimiliano, De Pietro Stefano. Subcutaneous anchoring device for securement of tunneled hemodialysis catheters: A first retrospective multicenter case series.. The journal of vascular access. 2026. DOI: 10.1177/11297298261417901.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.