OBJECTIVE

Deep learning (DL) has become state-of-the-art for blood glucose (BG) forecasting in type 1 diabetes (T1D). However, its black-box nature raises safety and reliability concerns regarding its use for therapeutic decision-support. This study aims to: (1) highlight potential risks associated with standard DL-based BG forecasting, and (2) address them with PhyNet, a physiology-constrained monotonic neural network.

METHODS

Two large-scale datasets (T1DEXI and MetaboNet, 848 subjects in total) were used to develop PhyNet-which enforces physiological consistency through a multi-branch structure and weight constraints-and compare it against six DL baselines (convolutional, recurrent, and transformer-based architectures). Models predicted BG levels up to 90-minute ahead using continuous glucose monitoring (CGM) data, carbohydrate intake, and insulin dosing, and were assessed for: (i) predictive accuracy with standard metrics, and (ii) adherence to physiological principles (i.e., carbohydrates increase BG, insulin lowers it) using explainable AI. Specifically, we evaluated model-predicted responses to varying carbohydrate and insulin intakes, and generated counterfactual explanations to identify model-recommended actions for avoiding adverse events.

RESULTS

At a 30-minute horizon, predictive accuracy was similar across models (RMSE: 19.39-21.00 mg/dL; Time Gain: 10.45-13.35 min). Despite this, only PhyNet consistently captured the physiological effects of carbohydrates and insulin, yielding 0% unsafe recommendations versus up to 64.3% for baselines.

CONCLUSION

Standard DL models can achieve state-of-the-art performance while failing to respect physiology, posing clinical risk. PhyNet preserves accuracy while enhancing physiological fidelity, supporting safer integration into T1D technologies.

SIGNIFICANCE: Evaluating physiological consistency alongside predictive accuracy is essential for responsible clinical translation of DL-based BG forecasting.

Для цитирования: Calzavara Andrea, Prendin Francesco, Cappon Giacomo, Favero Simone Del, Facchinetti Andrea. PhyNet: A Physiology-Constrained Monotonic Neural Network for Safe and Explainable Blood Glucose Forecasting.. IEEE transactions on bio-medical engineering. 2026. DOI: 10.1109/tbme.2026.3730324.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.