Rapid quantification of bile acids in serum by LC-MS/MS and application to serum bile acid profile in voriconazole administered patients with invasive fungal infections.

Yang Xuping, Qin Haoran, Ling Jing, Dong Lulu, Jiang Yan, Zou Sulan, Hu Nan

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

Disruption of bile acid homeostasis is implicated in the pathogenesis and progress of several liver diseases, including drug-induced liver injury (DILI). A rapid liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for quantifying 30 bile acids in human serum was developed and applied to analyze serum bile acid profile in voriconazole administered patients with invasive fungal infections.

METHODS

The stable isotope-coded bile acids were used as internal standards. The analytes in serum samples (50 μL) were extracted by protein precipitation and isolated by a Kinetex EVO C18 column (50 × 2.1 mm, 2.6 μm). The detection was performed using multiple reaction monitoring (MRM) in electrospray negative ionization mode.

RESULTS

All of the 30 bile acids were sufficiently separated within 10 min with good linearity (r > 0.99) over tested calibration ranges. The accuracy and precision values were in the range of 85.42-114.3% and 1.8-13.8%, respectively. The matrix effect, recovery, stability, and dilution integrity all met the acceptance criteria. Serum bile acid profile changed in patients with supratherapeutic voriconazole concentration (>10 μg/mL).

CONCLUSIONS

This LC-MS/MS method for the quantification of 30 bile acids in human serum might apply a new analytical approach for liver function evaluation.

Для цитирования: Yang Xuping, Qin Haoran, Ling Jing, Dong Lulu, Jiang Yan, Zou Sulan, Hu Nan. Rapid quantification of bile acids in serum by LC-MS/MS and application to serum bile acid profile in voriconazole administered patients with invasive fungal infections.. Bioanalysis. 2026. DOI: 10.1080/17576180.2026.2625865.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.