Safety and tolerability of once-daily tiotropium Respimat(®) as add-on to at least inhaled corticosteroids in adult patients with symptomatic asthma: A pooled safety analysis.

Dahl Ronald, Engel Michael, Dusser Daniel, Halpin David, Kerstjens Huib A M, Zaremba-Pechmann Liliana, Moroni-Zentgraf Petra, Busse William W, Bateman Eric D

Клиническое исследование II фазыКлиническое исследование III фазыСтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Tiotropium, a long-acting anticholinergic bronchodilator, has demonstrated efficacy and safety as add-on therapy to inhaled corticosteroids (ICS), with or without other maintenance therapies, in patients with symptomatic asthma.

OBJECTIVE

To evaluate safety and tolerability of tiotropium delivered via the Respimat(®) device, compared with placebo, each as add-on to at least ICS therapy, in a pooled sample of adults with symptomatic asthma at different treatment steps.

METHODS

Data were pooled from seven Phase II and III, randomised, double-blind, parallel-group trials of 12-52 weeks' treatment duration, which investigated once-daily tiotropium Respimat(®) (5 μg, 2.5 μg) versus placebo as add-on to different background maintenance therapy including at least ICS. Adverse events (AEs) including serious AEs were assessed throughout treatment + 30 days after the last dose of trial medication.

RESULTS

Of 3474 patients analysed, 2157 received tiotropium. The percentage of patients with AEs was comparable between treatment groups: tiotropium 5 μg, 60.8%; placebo 5 μg pool, 62.5%; tiotropium 2.5 μg, 57.1%; placebo 2.5 μg pool, 55.1%. Consistent with the disease profile, the most frequent AEs overall were asthma, decreased peak expiratory flow rate (both less frequent with tiotropium) and nasopharyngitis. Overall incidence of dry mouth, commonly associated with use of anticholinergics, was low: tiotropium 5 μg, 1.0%; placebo 5 μg pool, 0.5%; tiotropium 2.5 μg, 0.4%; placebo 2.5 μg pool, 0.5%. The percentage of cardiac disorder AEs was comparable between tiotropium and placebo: tiotropium 5 μg, 1.4%; placebo 5 μg pool, 1.4%; tiotropium 2.5 μg, 1.4%; placebo 2.5 μg pool, 1.1%. The proportions of patients with serious AEs were balanced across groups: tiotropium 5 μg, 4.0%; placebo 5 μg pool, 4.9%; tiotropium 2.5 μg, 2.0%; placebo 2.5 μg pool, 3.3%.

CONCLUSION

Tiotropium Respimat(®) demonstrated safety and tolerability comparable with those of placebo, as add-on to at least ICS therapy, at different treatment steps in adults with symptomatic asthma.

Для цитирования: Dahl Ronald, Engel Michael, Dusser Daniel, Halpin David, Kerstjens Huib A M, Zaremba-Pechmann Liliana, Moroni-Zentgraf Petra, Busse William W, Bateman Eric D. Safety and tolerability of once-daily tiotropium Respimat(®) as add-on to at least inhaled corticosteroids in adult patients with symptomatic asthma: A pooled safety analysis.. Respiratory medicine. 2016. DOI: 10.1016/j.rmed.2016.07.001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.