MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1142/s242483552250059x

Медицинская библиотека · The journal of hand surgery Asian-Pacific volume · 2022

Arc Centre Distance Change after Treatment of Complex Transverse Olecranon Fractures with a Large Impacted Articular Fragment Treated with Tension Band Wiring and Bone Graft.

Kim Min B, Lee Seung H, Lee Jeong H, Yang Hanbual

СтатьяОбзорПеревод в очереди

Аннотация

Background

The treatment of complex transverse olecranon fractures (CTOFs), also known as olecranon fractures with the impacted articular fragments (IAF), was reported recently. We fix IAFs with absorbable pins supported by autologous bone graft followed by olecranon fracture fixation. We have used the arc centre distance (ACD) method to evaluate the congruency of this concentric hinge joint. The aim of this study is to present the outcomes of this fixation technique and evaluate the value of the ACD method.

Methods

We reviewed 26 cases of CTOF treated at our hospital from 2014 to 2020. The functional outcome and range of motion of the elbow joint was measured by MEPS (Mayo Elbow Performance Score). We measured the ACD of each fragment of the ulnotrochlear joint [coronoid process (CP), IAF and olecranon process (OP)] with the CT image taken at 15 months postoperatively on average.

Results

The mean arc of elbow motion was 3º to 132º. The mean MEPS at 1 year postoperatively was 94, and 25 of 26 cases (96%) achieved a good or excellent outcome. Twelve patients, who took the elbow CT at least more than 3 months post-operatively, were included for ACD measurement. The postoperative joint incongruency of each fragment was as follows, 0.39 ± 0.70, 0.40 ± 0.69 and 0.29 ± 0.72 mm (CP, IAF and OP, respectively) according to the ACD method. The ACD value for each fragment was significantly different before and after the surgery (p < 0.05).

Conclusions

Accurate reduction of IAF with absorbable pins completed by tension band wiring with autogenous bone grafting can be an effective technique for CTOF with a large IAF. The restoration of the joint improved ACD. Level of Evidence: Level IV (Therapeutic).

Для цитирования: Kim Min B, Lee Seung H, Lee Jeong H, Yang Hanbual. Arc Centre Distance Change after Treatment of Complex Transverse Olecranon Fractures with a Large Impacted Articular Fragment Treated with Tension Band Wiring and Bone Graft.. The journal of hand surgery Asian-Pacific volume. 2022. DOI: 10.1142/s242483552250059x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.