Increased risk of volume overload with plasma compared with four-factor prothrombin complex concentrate for urgent vitamin K antagonist reversal.

Refaai Majed A, Goldstein Joshua N, Lee Martin L, Durn Billie L, Milling Truman J, Sarode Ravi

Клиническое исследование III фазыСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Plasma is commonly used for vitamin K antagonist (VKA) reversal, but observational studies suggest that it is associated with transfusion-related adverse reactions (e.g., volume overload). However, this issue has not previously been addressed in a randomized controlled trial (RCT).

STUDY DESIGN AND

METHODS

Factors associated with volume overload were examined using data from two Phase IIIb RCTs comparing plasma with four-factor prothrombin complex concentrate (4F-PCC, Beriplex/Kcentra, CSL Behring) for urgent VKA reversal. VKA-treated patients with major bleeding (NCT00708435) or requiring an urgent surgical or invasive procedure (NCT00803101) were randomly assigned (1:1) to receive either plasma or 4F-PCC, concomitant with vitamin K. Adverse events (AEs) and serious AEs were prospectively captured up to Day 10 and 45, respectively. Volume overload predictors were evaluated on a univariate and multivariate basis.

RESULTS

A total of 388 patients (4F-PCC, n = 191; plasma, n = 197) were enrolled. Volume overload occurred in 34 (9%) patients (4F-PCC, n = 9; plasma, n = 25). In univariate analyses, use of plasma (vs. 4F-PCC), use of nonstudy plasma and/or platelets, race, history of congestive heart failure (CHF), and history of renal disease were associated with volume overload. In multivariate analyses, use of plasma (vs. 4F-PCC), history of CHF, and history of renal disease were independent volume overload predictors. In an additional analysis restricted to volume overload events recorded up to Day 7, only use of plasma (vs. 4F-PCC) was an independent volume overload predictor.

CONCLUSIONS

After adjusting for other potential risk factors, plasma use was independently associated with a greater risk of volume overload than 4F-PCC in patients requiring urgent VKA reversal.

Для цитирования: Refaai Majed A, Goldstein Joshua N, Lee Martin L, Durn Billie L, Milling Truman J, Sarode Ravi. Increased risk of volume overload with plasma compared with four-factor prothrombin complex concentrate for urgent vitamin K antagonist reversal.. Transfusion. 2015. DOI: 10.1111/trf.13191.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.