Persistent Cross-Institutional Domain Shift in Narrow-Band Imaging Classification of Colorectal Lesions and the Utility of Site-Specific Fine-Tuning.

Nomiya Hiroki, Kikuchi Hidezumi, Shimizu Takeshi, Nakano Saki, Asari Taka, Sawada Yohei, Igarashi Shohei, Higuchi Naoki, Tatsuta Tetsuya, Chinda Daisuke, Sasaki Yoshihiro, Sakuraba Hirotake

СтатьяПеревод в очереди

Аннотация

Background/

Objectives

Cross-institutional transfer of endoscopic deep learning models may be limited by acquisition and preprocessing differences. We reassessed persistent domain shift after correcting Facility B input linkage and validation design.

Methods

A preflight audit corrected two Facility B image-mask linkage omissions without changing the 402 source lesions or 469 still images. Criterion B was a qualitatively selected, Facility-B-informed HSV patch-selection adjustment; the same Tenengrad focus criterion was used at both facilities. Class-wise MMD2 was calculated using all three Facility A fold-specific feature extractors. Each Facility A source model was evaluated on the same corrected criterion B Facility B cohort. Facility B models were initialized from ImageNet and fully fine-tuned for four prespecified epochs under lesion-grouped three-fold cross-validation, with pooled out-of-fold patch-level evaluation. Historical Facility A internal results were descriptive only.

Results

Criterion B retained 142,878 Facility B patches. Residual MMD2 was greatest for SM1 (0.185) and SM2 (0.147). Cross-site accuracy, macro-F1, and balanced accuracy were 0.711, 0.397, and 0.422; site-specific values were 0.770, 0.472, and 0.473. Recall improved for BG, LG, and SM1 but decreased for HG and SM2.

Conclusions

Site-specific development partially improved aggregate local performance, but persistent domain shift and class-specific limitations remained; universal cross-institutional generalizability was not established.

Для цитирования: Nomiya Hiroki, Kikuchi Hidezumi, Shimizu Takeshi, Nakano Saki, Asari Taka, Sawada Yohei, Igarashi Shohei, Higuchi Naoki, Tatsuta Tetsuya, Chinda Daisuke, Sasaki Yoshihiro, Sakuraba Hirotake. Persistent Cross-Institutional Domain Shift in Narrow-Band Imaging Classification of Colorectal Lesions and the Utility of Site-Specific Fine-Tuning.. Cancers. 2026. DOI: 10.3390/cancers18183002.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.