Safety and Efficacy of Everolimus-Eluting Bioresorbable Vascular Scaffold Versus Second-Generation Drug-Eluting Stents in Real-World Practice.

Lee Joo Myung, Joh Hyun Sung, Choi Ki Hong, Hong David, Park Taek Kyu, Yang Jeong Hoon, Song Young Bin, Choi Jin-Ho, Choi Seung-Hyuk, Jeong Jin-Ok, Lee Jong-Young, Choi Young Jin, Chae Jei-Keon, Hur Seung-Ho, Bae Jang-Whan, Oh Ju-Hyeon, Chun Kook-Jin, Kim Hyun-Joong, Cho Byung Ryul, Shin Doosup, Lee Seung Hun, Hwang Doyeon, Lee Hyun-Jong, Jang Ho-Jun, Kim Hyun Kuk, Ha Sang Jin, Shin Eun-Seok, Doh Joon-Hyung, Hahn Joo-Yong, Gwon Hyeon-Cheol, SMART-REWARD Investigators

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The risk of device thrombosis and device-oriented clinical outcomes with bioresorbable vascular scaffold (BVS) was reported to be significantly higher than with contemporary drug-eluting stents (DESs). However, optimal device implantation may improve clinical outcomes in patients receiving BVS. The current study evaluated mid-term safety and efficacy of Absorb BVS with meticulous device optimization under intravascular imaging guidance.

METHODS

The SMART-REWARD and PERSPECTIVE-PCI registries in Korea prospectively enrolled 390 patients with BVS and 675 patients with DES, respectively. The primary endpoint was target vessel failure (TVF) at 2 years and the secondary major endpoint was patient-oriented composite outcome (POCO) at 2 years.

RESULTS

Patient-level pooled analysis evaluated 1,003 patients (377 patients with BVS and 626 patients with DES). Mean scaffold diameter per lesion was 3.24 ± 0.30 mm in BVS group. Most BVSs were implanted with pre-dilatation (90.9%), intravascular imaging guidance (74.9%), and post-dilatation (73.1%) at proximal to mid segment (81.9%) in target vessel. Patients treated with BVS showed comparable risks of 2-year TVF (2.9% vs. 3.7%, adjusted hazard ratio [HR], 1.283, 95% confidence interval [CI], 0.487-3.378, P = 0.615) and 2-year POCO (4.5% vs. 5.9%, adjusted HR, 1.413, 95% CI, 0.663-3.012, P = 0.370) than those with DES. The rate of 2-year definite or probable device thrombosis (0.3% vs. 0.5%, P = 0.424) was also similar. The sensitivity analyses consistently showed comparable risk of TVF and POCO between the 2 groups.

CONCLUSION

With meticulous device optimization under imaging guidance and avoidance of implantation in small vessels, BVS showed comparable risks of 2-year TVF and device thrombosis with DES.

TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT02601404, NCT04265443.

Для цитирования: Lee Joo Myung, Joh Hyun Sung, Choi Ki Hong, Hong David, Park Taek Kyu, Yang Jeong Hoon, Song Young Bin, Choi Jin-Ho, Choi Seung-Hyuk, Jeong Jin-Ok, Lee Jong-Young, Choi Young Jin, Chae Jei-Keon, Hur Seung-Ho, Bae Jang-Whan, Oh Ju-Hyeon, Chun Kook-Jin, Kim Hyun-Joong, Cho Byung Ryul, Shin Doosup, Lee Seung Hun, Hwang Doyeon, Lee Hyun-Jong, Jang Ho-Jun, Kim Hyun Kuk, Ha Sang Jin, Shin Eun-Seok, Doh Joon-Hyung, Hahn Joo-Yong, Gwon Hyeon-Cheol, SMART-REWARD Investigators. Safety and Efficacy of Everolimus-Eluting Bioresorbable Vascular Scaffold Versus Second-Generation Drug-Eluting Stents in Real-World Practice.. Journal of Korean medical science. 2023. DOI: 10.3346/jkms.2023.38.e34.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.