MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.contraception.2024.110771

Медицинская библиотека · Contraception · 2024

Three-year efficacy, safety, and tolerability outcomes from a phase 3 study of a low-dose copper intrauterine device.

Creinin Mitchell D, Gawron Lori M, Roe Andrea H, Blumenthal Paul D, Boraas Christy M, Hou Melody Y, McNicholas Colleen, Schreifels Mary Jo, Peters Kevin, Culwell Kelly, Turok David K, Copper 175mm(2) IUD Phase 3 Clinical Investigator Group

СтатьяКлиническое исследование III фазыМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVES

This study aimed to assess 3-year efficacy, safety, and tolerability of the Cu 175 mm2 intrauterine device (IUD).

STUDY

DESIGN

This single-arm trial recruited participants at risk of pregnancy aged 17 to 45 years at 42 U.S. centers to receive a Cu 175 mm2 IUD with a flexible nitinol frame. We assessed efficacy in participants aged ≤35 years at enrollment and assessed all other outcomes in the entire population. We calculated the Pearl Index (pregnancies/100 person-years) through 3 years as the primary efficacy outcome. The secondary outcomes included pregnancy percentages by life-table analysis, placement success, safety (adverse events), and tolerability.

RESULTS

Of 1620 enrollees, 1601 (98.8%) had successful IUD placement, with 1397 aged ≤35 years at enrollment. We observed a 1-year Pearl Index of 0.94 (95% CI 0.43-1.78) and 1-year and cumulative 3-year life-table pregnancy rates of 1.26% (95% CI 0.57%-1.95%) and 2.47% (95% CI 1.34%-3.60%), respectively. The most common adverse events included bleeding and pain. Over 3 years, 15.4% of participants discontinued due to bleeding or pain. Device expulsions occurred in 36 (2.2%) and 63 (3.9%) participants over 1 and 3 years, respectively. Eight related serious adverse events occurred, including five ectopic pregnancies and one each of uterine perforation, anemia, and uterine hemorrhage. One- and three-year continuation rates were 78.9% and 49.6%, respectively.

CONCLUSIONS

These data support efficacy, safety, and tolerability of the Cu 175 mm2 IUD during the first 3 years of use.

IMPLICATIONS: In this Phase 3 trial, the investigational Cu 175 mm2 demonstrated efficacy, safety, and tolerability with low rates of expulsion and discontinuation for bleeding and pain-related symptoms. This flexible, nitinol-framed, low-dose copper IUD comes preloaded and would expand contraceptive options beyond the single nonhormonal IUD currently available in the United States.

CLINICAL TRIAL: NCT03633799.

Для цитирования: Creinin Mitchell D, Gawron Lori M, Roe Andrea H, Blumenthal Paul D, Boraas Christy M, Hou Melody Y, McNicholas Colleen, Schreifels Mary Jo, Peters Kevin, Culwell Kelly, Turok David K, Copper 175mm(2) IUD Phase 3 Clinical Investigator Group. Three-year efficacy, safety, and tolerability outcomes from a phase 3 study of a low-dose copper intrauterine device.. Contraception. 2024. DOI: 10.1016/j.contraception.2024.110771.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.