MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1210/clinem/dgab464

Медицинская библиотека · The Journal of clinical endocrinology and metabolism · 2021

Second-tier Testing for 21-Hydroxylase Deficiency in the Netherlands: A Newborn Screening Pilot Study.

Stroek Kevin, Ruiter An, van der Linde Annelieke, Ackermans Mariette, Bouva Marelle J, Engel Henk, Jakobs Bernadette, Kemper Evelien A, van den Akker Erica L T, van Albada Mirjam E, Bocca Gianni, Finken Martijn J J, Hannema Sabine E, Mieke Houdijk E C A, van der Kamp Hetty J, van Tellingen Vera, Paul van Trotsenburg A S, Zwaveling-Soonawala Nitash, Bosch Annet M, de Jonge Robert, Heijboer Annemieke C, Claahsen-van der Grinten Hedi L, Boelen Anita

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

CONTEXT: Newborn screening (NBS) for classic congenital adrenal hyperplasia (CAH) consists of 17-hydroxyprogesterone (17-OHP) measurement with gestational age-adjusted cutoffs. A second heel puncture (HP) is performed in newborns with inconclusive results to reduce false positives.

OBJECTIVE

We assessed the accuracy and turnaround time of the current CAH NBS algorithm in comparison with alternative algorithms by performing a second-tier 21-deoxycortisol (21-DF) pilot study.

METHODS

Dried blood spots (DBS) of newborns with inconclusive and positive 17-OHP (immunoassay) first HP results were sent from regional NBS laboratories to the Amsterdam UMC Endocrine Laboratory. In 2017-2019, 21-DF concentrations were analyzed by LC-MS/MS in parallel with routine NBS. Diagnoses were confirmed by mutation analysis.

RESULTS

A total of 328 DBS were analyzed; 37 newborns had confirmed classic CAH, 33 were false-positive and 258 were categorized as negative in the second HP following the current algorithm. With second-tier testing, all 37 confirmed CAH had elevated 21-DF, while all 33 false positives and 253/258 second-HP negatives had undetectable 21-DF. The elevated 21-DF of the other 5 newborns may be NBS false negatives or second-tier false positives. Adding the second-tier results to inconclusive first HPs reduced the number of false positives to 11 and prevented all 286 second HPs. Adding the second tier to both positive and inconclusive first HPs eliminated all false positives but delayed referral for 31 CAH patients (1-4 days).

CONCLUSION

Application of the second-tier 21-DF measurement to inconclusive first HPs improved our CAH NBS by reducing false positives, abolishing the second HP, and thereby shortening referral time.

Для цитирования: Stroek Kevin, Ruiter An, van der Linde Annelieke, Ackermans Mariette, Bouva Marelle J, Engel Henk, Jakobs Bernadette, Kemper Evelien A, van den Akker Erica L T, van Albada Mirjam E, Bocca Gianni, Finken Martijn J J, Hannema Sabine E, Mieke Houdijk E C A, van der Kamp Hetty J, van Tellingen Vera, Paul van Trotsenburg A S, Zwaveling-Soonawala Nitash, Bosch Annet M, de Jonge Robert, Heijboer Annemieke C, Claahsen-van der Grinten Hedi L, Boelen Anita. Second-tier Testing for 21-Hydroxylase Deficiency in the Netherlands: A Newborn Screening Pilot Study.. The Journal of clinical endocrinology and metabolism. 2021. DOI: 10.1210/clinem/dgab464.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.